6.
Install 7" (17.8 cm) round vent mounting plate. Attach to
range hood with the 3.5 x 9.5 mm screws provided.
(Optional) The 7" (17.8 cm) round damper (supplied) can be
installed if desired or required. Remove tape from the damper
flap.
A. 7" (17.8 cm) round damper
B.3.5 x 9.5 mm screws
C. 7" (17.8 cm) round vent mounting plate
D. Round vent knockout
E. Rectangular vent knockout
NOTE: The 7" (17.8 cm) round vent mounting plate can
be installed up to 1" (2.5 cm) on either side of the hood
center to accommodate off center ductwork.
Power Supply Cable Installation
For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards
and local codes and ordinances. There must be enough
wiring from the fused disconnect (or circuit breaker) box to
make the connection in the hood electrical termina! box.
For optional power supply cord kit installations, follow the
instructions in the "Make Electrical Connection" section. See
the "Accessories" section for information on ordering.
NOTE: Do not reconnect power until the installation is
complete.
Remove the screw from the terminal box cover. Remove
terminal box cover and set aside.
A. Terminal box cover
B. Screw
Remove the power supply knockout from the top or rear of
the vent hood (depending on the incoming location of your
home power supply cable) and install a UL listed or CSA
approved 1%" strain relief.
A. Power supply knockout
Using 2 or more people, lift the hood into final position. Feed
enough electrical wire through the ¥" UL listed or CSA
approved strain relief to make connections in the terminal
box. Tighten the strain relief screws.
Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall so that the screws are in the neck of the slots.
Tighten the mounting screws, making sure the screws are in
the narrow neck of slots.
Connect ventwork to hood. Seal joints with vent clamps or
duct tape to make secure and airtight.
Check that back draft dampers work properly.
# mel eg
(it,
&
iCe
de
.
Make Electrical Connection
a8 inl ne nl
AWARNING
Xe
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.
Disconnect power.
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) ground wire
E. Home power supply cable or
power cord accessory kit
F. UL listed or CSA approved
Ya" strain relief
G. Green ground screw