Descargar Imprimir esta página

Cembre B1350-C-KV Manual De Uso Y Mantenimiento página 8

Herramienta hidráulica de crimpado a batería
Ocultar thumbs Ver también para B1350-C-KV:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

NOTE:
To display the momentary force or pressure during
the work cycle, select the appropriate display from the
menu (Ref. to § 4). When the operating button is released
before the motor stops automatically, the display will show
the peak force (Fp) or the peak pressure (Pp) reached at
that instant.
To complete the work, press the operating button again until the motor stops automatically; the display
will show the maximum force or pressure reached followed by "OK" to confirm correct operation.
The display "ERROR", combined with a beep and the LEDs flashing, indi-
= 125.2 kN
F
m
cates an incorrect crimping procedure caused by the work cycle being
= 102.3 kN
p
interrupted before the control parameters (force/pressure) of the tool
are reached.
= 692 bar
P
m
This error appears when the pressure release button has been operated and the tool has already
= 565 bar
p
reached a pressure >100 bar. In this case, repeat the compression by pressing and holding the op-
erating button until the motor stops automatically.
max.
2.4) Release of dies
BATTERY
By operating the pressure release button (5) (Ref. to Fig. 4), the ram will retract and open the dies.
To take the dies off their guide, sliding them pushing the release pins (12 and 14) (Ref. to Fig. 2).
2.5) LED Worklights
Whilst the tool is in operation, the compression area is illuminated by two high luminosity LED
Worklights that switch off automatically at the end of the cycle.
The LED Worklights can be disabled by following the procedure described in § 4.2.
LED
ON
2.6) Head rotation
LED
For ease of operation, the tool head can rotate through 180°, allowing the operator to work in the
OFF
most comfortable position.
Do not attempt to rotate the head when the hydraulic circuit is pressurised.
2.7) Capacitive touch button for menu selection
This button is located under the display and allows selection of various
screens (Ref. to § 4); it only works when the display is on.
Wearing gloves or using other objects may inhibit the operation of the
button, therefore use a bare finger to apply only a light touch.
F
= 125.2 kN
m
Fp = 94.5 kN
F
= 14.07 ton
m
Fp = 10.61 ton
= 125.2 kN
m
OK
P
= 692 bar
m
= 692 bar
m
Pp = 522.3 bar
OK
P
= 10037 psi
m
min.
Pp = 7575 psi
BATTERY
BATTERY
1000
-12000
B1350
13AB485
3 SEC.
BATTERY 
BATTERY
RESET
SW:S1J41413
LED
OFF
3 SEC.
LED
ON
F
= 125.2 kN
m
F
= 102.3 kN
p
P
= 692 bar
m
P
= 565 bar
p
max.
BATTERY
LED
13001
ON
LED
OFF
F
= 125.2 kN
m
OK
P
= 692 bar
m
OK
min.
BATTERY
ERROR
001
F
= 125.2 kN
m
Fp = 94.5 kN
002
F
= 14.07 ton
m
Fp = 10.61 ton
003
P
= 692 bar
m
Pp = 522.3 bar
004
P
= 10037 psi
m
Pp = 7575 psi
BATTERY
1000
-12000
B1350
13AB485
3 SEC.
8

Publicidad

loading