EXISTING CONSTRUCTION (BELOW CEILING APPLICATION) INSTALLATION INSTRUCTIONS
9. Strip 1/2 in. of insulation from wire ends. Grip the wire
firmly and push the stripped end of the wire into the
open port of two-port quick connect (GG) or three-port
quick connect (HH). Use only one stripped end of the
wire per port. Verify the stripped end of the wire is fully
inserted to the back of two-port quick connect (GG) or
three-port quick connect (HH).
Hardware Used
G
Two-port Quick Connect
~
x4
4JD
Three-port Quick
Connect~
X
1
10. Install the previously removed wire housing cover (K)
into the housing (A) and secure using the wire housing
screw (II). Ensure all of the wiring connections are
inside of the housing (A) or under the wire housing
cover (K).
Hardware Used
0
Wire Housing Screw
~
Proceed to FINAL INSTALLATION INSTRUCTIONS
below.
FINAL INSTALLATION INSTRUCTIONS
X
1
1. Install the motor assembly (B) into the housing (A) by
putting the preassembled flange on the motor assembly
(B) into the slide guide on the housing (A).
Important: Hold the motor in place to prevent it from
falling out.