Descargar Imprimir esta página

Pulsar G65BN Manual De Instrucciones página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

Changing Oil (See Fig 19)
Run the Generator until the Engine is warm, then shut OFF.
Place generator on a level surface.
Remove the crankcase dipstick.
Place an oil pan underneath the oil drain hole to collect used oil.
Remove the oil drain plug and allow oil to drain completely.
Reinstall oil drain plug, tighten securely.
Carefully add SAE 30 or 10W-30 to empty reservoir until the oil reaches the
threads of the oil fill hole (Crankcase Dipstick hole).
Replace crankcase dipstick.
Oil Recommendations
Do not use special additives.
Outdoor temperatures can affect proper oil viscosity for the engine.
Use the chart to select the best viscosity for the outdoor temperature range
expected.
Note:
Below 40 F
*
Above 80 F
*
*
Check oil level more frequently
F
104
*
86
68
50
32
14
-4
-22
(4 C) the use of SAE 30 will result in hard starting.
(27 C)
the use of 10W -30 may cause increased oil consumption.
.
MAINTENANCE
*
*
18
Oil Fill & Dipstick
Oil drainage plug
Fig 19
C
40
30
20
10
0
-10
-20
-30

Publicidad