Fig. 8B
Fi 8
Fig. 9
If AC is Blocked by Storm Window
Storm window
1-1/2"min
frame or other
(38 mm)
obstruction.
Removing AC From Window
• Turn AC off, and disconnect power cord.
• Remove sash seal from between windows, and unscrew safety lock.
• Remove screws installed through frame and frame lock.
• Close (slide) side panels into frame.
• Keeping a firm grip on air conditioner, raise sash and carefully remove.
• Be careful not to spill any standing water while lifting unit form window. Store parts
WITH air conditioner.
WWK05CR to WWK12CR
Fig. 8C
Fig. 10
Fig. 11
SASH
Board thickness
as required, for
proper pitch to rear,
along entire
sill. Fasten with nails
or screws.
B2: For Vinyl-Clad windows:
Drive 1/2" (12.7 mm)
locking screws through
the frame lock and into
the window sash (Fig.
8B).
NOTE: Before driving
the screws, use a drill to
drill 5 holes through the
holes in the frame lock
and frame extensions
into the windows sash
as shown (Fig. 8B/8C).
C. To secure lower sash in
FOAM SEAL
place, attach right angle
sash lock with 3/4" (19
mm) or 1/2" (12.7 mm)
screw as shown (Fig. 9).
D. Cut Window sash seal
foam and insert it in
the space between the
upper and lower sashes
(Fig. 10).
Add wood as shown in Fig. 11, or remove
storm window before air conditioner is
installed.
If storm window frame must remain,
be sure the drain holes or slots are not
caulked or painted shut. Accumulated
rain water or condensation must be
allowed to drain out.