F. Mount the detector
Determine correct mounting location
A combination detector is a smoke detector and
carbon monoxide detector in one. Smoke rises
and carbon monoxide spreads through the air.
Due to this difference, the ideal mounting
location depends entirely on your situation.
Check figure 2 and 3 for correct mounting
locations. Most EU countries require smoke
detectors on all floors and escape routes.
Smoke spreads horizontally after rising to the
ceiling, so install the detector in middle of the
ceiling.
If the length of the room or the hall is beyond
10 meters, you need to install multiple
(smoke) alarms.
In rooms with a combustion appliance, place
the
detector
between 1-3 meters from the CO source.
Do not mount detector on these locations
Areas with high-humidity (e.g. kitchens,
bathrooms), insects, dust/dirt, easily polluted
and high-temperature.
Within 1.5 meters of lamps, next to air outlets
(e.g.
doors/windows),
heating.
In top of room with sloping roofs, in the
corner of the room or other dead-air spaces.
Places with difficult access, making it difficult
to operate the test function.
Mounting instructions
Step 1: Twist the mounting bracket counterclockwise off the detector by aligning the lines (Figure 1).
Step 2: Put the bracket in the mounting position and mark the 2 screw holes. Drill two 5mm
mounting holes and insert the two plastic anchor plugs by hammer. Screw the mounting bracket
to the ceiling or the wall.
Step 3: Attach the detector to the mounting bracket and turn clockwise to lock the detector.
05
at
a
horizontal
fans
and
distance
central
Figure 2: Recommended mounting locations
Figure 3: Recommended mounting locations