920-090-05 (12-05)
Test the power cord
All Friedrich room air conditioners
are shipped from the
factory
with a Leakage
Current
Detection
Interrupter
(LCDI) equipped power cord. The LCDI device meets
the UL and NEC requirements
for cord connected
air
conditioners effective August 2004.
To test your power supply cord:
1. Plug power
supply cord into a grounded
3 prong
outlet.
2. Press RESET (See Figure 2).
3. Press TEST (listen for click; Reset button trips and
pops out).
4. Press aud release RESET (listen for click; Reset button
latches and remains in). The power supply cord is ready
tbr operation.
NOTE:
LCDI device is not intended
to be used as a
switch.
Once plugged in the unit will operate normally without the
need to reset the LCDI device.
If the device thils to trip when tested or if the power supply cord
is damaged it must be replaced with a new supply cord froln
the manutZacturer.We recommend you contact our Technical
Assistance
Line at (800) 541-6645 ext. 662. To expedite
service, please have your model and serial number available.
MODEL
PLUG FACE
CIRCUIT RATING OR
TIME DELAY FUSE
AMP
VOLT
15
125
15
250
20
250
N° NEMA
SS08 • SS10 • SS12 • SS14
5-15P
@
SS12 • SS16 • SM18 • SM21
6-15P
@
SM24
6-20P
@
Figure
1
--
Reset Button
Figure
2
Forthe bestcoolingperformance and highestenergy efficiency
Keep the filter clean
Make
sure that your air conditioner
is always in top
performing
condition
by cleaning
the filter regularly.
Instructions
for removing
and cleaning
the tilter can be
found on page 7.
Providegoodair flow
Make sure the airflow to and from the unit is clear. Your
air conditioner puts the conditioned air out at the top of the
unit, and takes in unconditioned
air at the bottom. Airflow
is critical to good operation. It is just as important
on the
outside of the building that the airflow around the unit
exterior is not blocked.
Insulation
Good insulation will be a big help in maintaining
desirable
comfort levels. Doors should have weather stripping. Be
sure to caulk around doors and windows.
Properinstallationof sealgasket
Make sure the seal gasket has been installed
properly to
minimize
noise and improve efficiency. If the seal gasket
has not been installed,
please refer to your installation
instruction manual.
Unit placement
It your air conditioner can be placed in a window or wall
that is shaded by a tree or another building, the unit will
operate even more efficiently. Using drapes or blinds on
the sunny side of the dwelling will also add to your unit's
efficiency.