Descargar Imprimir esta página

VICAIR ACTIVE 02 Manual Del Usuario página 8

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Disinfecting your Vicair Active O2
Warning! In case of soiling with body fluids, and
when transferring the product to another user,
the product must be disinfected to avoid cross
contamination. Clean the Active O2 cover, foam
inlay and SmartCell liners as instructed above.
Preferably use an anti-bacterial detergent. After
cleaning spray your cover, foam inlay liner and
SmartCell liners with a disinfectant. Bend the
cover compartments outwards to make sure the
spray gets into the gaps.
(Re)assembling your Vicair Active O2
The Vicair Active O2 is fully assembled on
delivery. When it needs to be (re)assembled, for
instance after cleaning, follow the assembly
instructions underneath. The instructions
correspond to image i (I, II & III) on the Quick
Installation Guide.
Placing the foam inlay in the Vicair Active O2
cover (image i - I)
Caution! Do not use the foam inlay without the
foam inlay liner.
Completely open the zipper at the front of
the Active O2 cover.
Place the foam inlay in the Active O2 cover,
the sloping side pointing to the back of the
cushion and the contoured side on top.
Close the zipper. Make sure you do not
damage the foam inlay liner.
Adjusting the number of SmartCells in the
SmartCell liners (image i - II)
Warning! Vicair B.V. recommends to adjust the
filling grade under the direct supervision of
your therapist or Assistive Technology
Professional.
8
The number of SmartCells in each SmartCell
liner depends on the size of the cushion. You
can find the default filling grade on the label
inside the cushion cover. When it's necessary to
adjust the number of SmartCells, follow these
steps:
Open the SmartCell liner's zipper and add or
remove the desired number of SmartCells.
Close the zipper. Make sure that you do not
damage the SmartCells.
Placing the SmartCell liners in the Vicair Active
O2 cover (image i - III)
Warning! Make sure the SmartCell liners are
placed in the correct compartment (see
SmartCell liner label).
Completely open the zipper at the back of
the cushion cover.
Place the SmartCell liners in the cover. Make
sure you place the correct SmartCell liner in
each compartment. The SmartCell liner's
label states where it should be placed.
Close the zipper. Make sure that you do not
damage the SmartCell liners.
REPORTING OF SERIOUS INCIDENTS
Serious incidents from use of Vicair products
should be reported to the manufacturer and the
relevant competent authority.
WARRANTY
Please see www.vicair.com for complete
information on warranty processes, terms and
conditions.
Vicair B.V. offers a limited warranty against
defects in workmanship and materials,
provided the product has been used normally.
Any damage arising from abnormal use, or
caused by improper handling, cleaning, or
negligence, is excluded from this warranty.

Publicidad

loading