v
SYSTEM AIR PURGE PROCEDURE
IMPORTANT: BEFORE FIRST USE
Perform the following Air Purge Procedure to remove any air that may have been introduced into the hydraulic
system as a result of product shipment and handling. This step is to be completed without any weight on the
jack.
1. Turn release valve counterclockwise on full turn to
the open position.
2. Rapidly pump the pedal 6-8 times. Leave handle
in down position to expose oil fill plug.
Release valve
3. With a flat blade screwdriver, push the oil fill plug
slightly to the side to purge trapped air from system.
(Use caution not to tear or puncture the oil plug.)
4. Turn release valve clockwise to the closed position.
5. Jack is now ready for use. Check for proper pump
action.
4
Release valve