Installation
Instructions
INSTALLING THE WATER LINE (cont.)
[] FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water pipe with
the pipe clamp.
Pipe Clamp
Saddle-Type J
Shutoff Valve
VerticalCold
Water Pipe
NOTE: Commonwealth
of Massachusetts
Plumbing
Codes 248CMR shall be adhered
m. Saddle valves
are illegal and use is not permitted
in Massachusetts.
Consult with your licensed plumben
[] TIGHTEN
THE PIPE CLAMP
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE:
Do not overtighten
or you may crush
the
tubing.
Washer
Pipe Clamp___
_lniet
End
Clamp Screw _
[] ROUTE THE TUBING
Route tile tubing between
the cold water line and
the refiigerator.
Route tile tubing through
a hole drilled in tile wall
or floor (behind
the refrigerator
or adjacent
base
cabinet)
as close to the w-all as possible.
NOTE:
Be sure
there
is sufficient
extra
tubing
(about
8" [2.4 m] coiled
into 3 turns
of about
10"
[25 cm]
diameter)
to allow the refrigerator
to move
out fi'om the wall after ins 'tallation.
[] CONNECT
THE TUBING
TO THE
VALVE
Place the compression
nut and ferrule
(sleeve) for
copper tubing onto the end of tile tubing and
connect
it to the shutuff valve.
Make sure the tubing is flflly inserted
into the valve.
Tighten
the compression
nut securely.
For plastic tubing from a GE SmartConnect
TM
Refrigerator
Tubing kit, insert the molded end
of the tubing into the shutoffvalve
and tighten
compression
nut until it is hand tight, then tighten
one additional
turn with a wrench. Overtightening
may cause leaks.
Nut
Saddle-Type --\
Shutoff Valve
SmartConnect
TM
Tubing
PackingNut
Outlet Valve
\
Ferrule(sleeve}
NOTE: Commonweahh
of Massachusetts
Plumbing
Codes 248CMR shall be adhered
to. Saddle valves
are illegal and use is not permitted
in Massachusetts.
Consult with your licensed plumbm:
[] FLUSH OUT THE TUBING
Turn the main water supply on and flush out the
tubing until the water is clear.
Shut the water off at the w-ater valve after about
one quart (1 liter) of water has been flushed
through
the tubing.
18