2. Safety
II 1/2 GD EEx d IIC T195 °C IP 65
resp. II 1/2 G EEx d IIC T3
II 1/2 GD EEx d IIC T290 °C IP 65
resp. II 1/2 G EEx d IIC T2
II 1/2 GD EEx d IIC T440 °C IP 65
resp. II 1/2 G EEx d IIC T1
1 fault safety (e.g. with sensor supply circuit
"ib")
II 2 GD EEx d IIC T80 °C IP 65
resp. II 2 G EEx d IIC T6
II 2 GD EEx d IIC T95 °C IP 65
resp. II 2 G EEx d IIC T5
II 2 GD EEx d IIC T130 °C IP 65
resp. II 2 G EEx d IIC T4
II 2 GD EEx d IIC T195 °C IP 65
resp. II 2 G EEx d IIC T3
II 2 GD EEx d IIC T290 °C IP 65
resp. II 2 G EEx d IIC T2
II 2 GD EEx d IIC T440 °C IP 65
resp. II 2 G EEx d IIC T1
*1 When using multiple sensor resistors (or several single resistors) and operating them
simultaneously, the sum of the individual power values must not exceed the value of the max.
permissible power specified in the table.
*2 The minimum neck length is to be defined as the distance between the lower edge of the
connection head and the heat-emitting surface.
*3 When using a transmitter or a current loop signal, the permissible ambient temperature range
is to be taken from the corresponding approval. In each case the lowest temperature level of
the various components used applies.
Electrical data
Power and signal circuit
P
at sensor = see table "Equipment Category classification"
max
P
in head
= 2 W
max
2.4 Special hazards
WARNING!
Observe the information given in the applicable type examination certificate and the
relevant country-specific regulations for installation and use in potentially explosive
atmospheres (e.g. IEC 60 079-14, NEC, CEC). Non-observance can result in serious
injury and/or damage to equipment. For additional important safety instructions for
insturments with ATEX approval see chapter "7. Notes for mounting and operating in
hazardous areas".
WARNING!
For hazardous media such as oxygen, acetylene, flammable or toxic gases or liquids,
and refrigeration plants, compressors, etc., in addition to all standard regulations, the
appropriate existing codes or regulations must also be followed.
WIKA Operating Instructions Model TR10-L/TC10-L EEx d
148
138
224
214
344
334
50 mW
100 mW
250 mW
78
75
68
93
90
83
128
125
118
193
190
183
288
285
278
438
435
428
50 mm
-20 ... 100 °C
100 mm
-20 ... 100 °C
100 mm
-20 ... 100 °C
500 mW
59
-
-20 ... 55 °C
74
-
-20 ... 70 °C
109
20 mm
-20 ... 100 °C
174
50 mm
-20 ... 100 °C
269
100 mm
-20 ... 100 °C
419
100 mm
-20 ... 100 °C
GB
7