7
TROUBLESHOOTING
PROBLEM / SYMPTOM
If engine doesn't start,
check that:
If engine starts but there is
no power at receptacles,
check that:
If engine starts but runs
erratically, check that:
PORTABLE GENERATOR
4.
Remove the screws and remove the cover.
5.
Drain the fuel from the carburetor by loosening the drain screw on the carburetor
float chamber.
Turn the knob switch to "OFF".
6.
7.
Tighten the drain screw.
8.
Install the cover and tighten the screws.
Turn the fuel tank cap air vent knob to "OFF" after the engine has completely
9.
coolled down.
REASON / REMEDY
▪ Engine switch is on "Start".
▪ Fuel valves under fuel tank and on engine are
▪ Fuel tank has fuel.
▪ Choke lever is in correct position. Choke should
▪ All loads are disconnected from generator.
▪ Spark plug is in good condition.
▪ Spark plug cap is tight.
▪ Engine oil level is adequate
▪ Circuit breaker is closed.
▪ Connector from generator to control panel is tight.
▪ Hose routing from the fuel tank to the engine is
Note:
The installation and major repair work shall be carried out only by specifically
trained person.
open.
be closed when starting a cold engine.
correct. For proper operation, the hose must run
through the bushing in the lifting bracket. Refer to
the Parts Book for illustration.
en
GEEL 2i