INDICATOR LIGHT:
The control unit allows a 24 Vdc indicator light to be connected to display
the status of the gate opener.
Indicator light off: gate closed
Indicator light on: gate open
Indicator light slow blinking: opening movement; rapid blinking: closing
movement.
Changing as Flashing light output.
OPERATION WITH TIMER:
The control unit allows a timer to be connected in place of the open – close
pushbutton.
E.g.: at 08.00 am the timer closes the contact and the control unit
commands an opening movement; at 06.00 pm the timer opens the
contact and the control unit commands a closing movement. From 08.00
am – 06.00 pm at the end of the opening cycle, the control unit disables
the flashing light, automatic closing and the remotes.
ELECTRIC LOCK CONTROL OUTPUT:
The control unit features an output to control a 12Vdc 15W max electric
lock. The command is switched on at each initial opening movement for a
period of 2 seconds.
MOTOR 1 AND MOTOR 2 DIRECTION OF RUN
CONTROL
Important Note: Warning: change the settings of dip-switches SW1
and SW2 with the control unit off and only subsequently repeat the
control unit programming procedure.
The electronic control unit is equipped with dip-switches that can be used
to change the direction of run of each connected motor without rewiring the
electrical connections: dip-switch 1 controls operator 1 while dip-switch 2
SW2
SW2
controls operator 2.
ON
ON
SW2
SW2
ON
ON
1
2
1
2
INV
INV
INV
INV
OFF
OFF
MOT 1
OFF
1
2
1
2
INV
INV
INV
INV
OFF
OFF
MOT 1
OFF
M1 OR M2 DELAY CONTROL AND ENABLING
OF 1 OR 2 MOTORS
The electronic control unit is equipped with a dip-switch SW1 that is used
to select operation with 1 or 2 motors and to define which of the two starts
first and which starts second.
SW1
SW1
ON
ON
SW1
SW1
ON
ON
1
2
1
2
1
NOT
2
MOTOR
MOTOR
CONSID.
MOTORS
2 DELAY
1
2
1
2
1
NOT
2
RITARDO
MOTORE
CONSID.
MOTORI
MOT. 2
PROGRAMMING:
SELECT Key: selects the type of function to store; the selection is
indicated by blinking of the LED.
Press the key twice to go to the required function. The selection remains
active for 10 seconds shown by blinking of the LED; when this interval
elapses, the control unit returns to the original state.
24
COMUNELLO ®Copyright 2014 - All right reserved
SW2
SW2
ON
ON
SW2
SW2
ON
ON
1
2
1
2
INV
INV
INV
INV
OFF
MOT 2
MOT 1
MOT 2
1
2
1
2
INV
INV
INV
INV
OFF
MOT 2
MOT 1
MOT 2
SW1
ON
SW1
ON
1
2
2
MOTOR
MOTORS
1 DELAY
1
2
2
RITARDO
MOTORI
MOT. 1
SET Key: programs the information in accordance with the function type
preselected with the SEL key.
IMPORTANT: The SET key function can be replaced by the remote if
programmed beforehand (CODE LED on).
Programming enabled only when safety devices are not active
MAIN MENÙ
The control unit is factory set to allow the selection of several important
functions.
L1
STEP BY STEP
L2
CODE TX
L3
CONDO
L4
MOTOR TIME
Programmed time
L5
PAUSE TIME
With automatic closing
L6
DELAY
L7
AUTOM PRG
LEV
MENU
1. STEP BY STEP:
In the default configuration the control unit is set with "Automatic" operating
logic enabled (LED n1 off); if the "Step-by-Step" operating logic is required
(LED n1 on), proceed as follows; use the SELECT key to select blinking
LED n1 and then press the SET key: LED n1 becomes steady on and
programming will be completed.
If the "Step-by-Step 1" operating logic is required, repeat the operation
above described, by pressing the SEL key twice instead only one (to obtain
the quick blinking of LED. Repeat the procedure if you wish to restore the
previous configuration.
2. TX CODE: (Remote control code):
Up to 120 remotes with different codes of either the fixed or rolling code
type can be saved on the control unit.
Programming:
Programming of the transmission code is performed as follows: use the
SELECT key to select blinking LED L2. Press SET once; the LED will
change its blinking mode (longer 1 0 1 0) to show that the
first level is being saved. On sending the selected code with the required
remote, the CODE LED will remain steady on to indicate that programming
will be completed.
To save the code for pedestrian opening / single leaf, proceed as follows:
use the SELECT key to select blinking CODE LED L2. Press SET twice
consecutively; the LED will change its blinking mode (1 1 0 1 1 0) to show
that
the pedestrian code is being saved. On sending the selected code with the
required remote, the CODE LED L2 will remain steady on to indicate that
programming will be completed.
To save the code for the 2nd AUX channel proceed as follows: use the
SELECT key to select blinking LED L2. Press SET 3 times consecutively;
the LED will change its blink mode (1 1 1 0 1 1 1 0) to show that the 2nd
AUX channel code is being saved. On sending the selected code with the
required remote, LED L2 will remain steady on to indicate that programming
will be completed.
If all 120 codes have been saved, repeating the programming operation will
cause all the programming LEDs to start blinking to signal that no further
codes can be saved.
Deletion:
Use SELECT to go to LED L2; activate blinking of the code to be deleted
(CODE or PEDESTRIAN or 2nd AUX channel as identified by the associated
blinking mode); press and hold down SET for > 5 s. After this interval, the
LED will switch off for 2 seconds and the procedure is completed. If all
CODE and PEDESTRIAN codes are deleted, the LED will remain off.
If only PEDESTRIAN or 2nd CH codes remain stored, the LED blinking
mode will change (1 1 1 1 0 1 1 1 1 0)
Rule of the first saved Remote control:
When programming remotes the following rule is applied: if the first remote
to be saved is a rolling code type, the receiver will subsequently accept only
rolling code remotes, thus providing enhanced anti-intrusion security; if the
first remote to be saved is a fixed code type, the receiver will subsequently
accept both fixed code remotes and rolling code remotes.
3. CONDO:
The Condominium function means that during the opening movement or
during the pause time the control unit will not respond to commands sent
Step-by-Step
Automatic
Code entered
No code
ON
OFF
30 sec.
Without automatic closing
ON
OFF
ON
OFF
ON

Publicidad

loading