EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed
as follows: select blinking LED LEV and press SET 3 times. The LED will
start blinking alternately 1 1 1 0 1 1 1 0. This means there will be 30
seconds to select the functions of Extended Menu 3 using the SEL and
SET keys; once an additional 30 seconds have elapsed the control unit
reverts to the main menu.
L1
SOFT STOP
L2
SOFT START
L3
RELEASE STROKE
L4
SLAM LOCK
L5
ELS / PED CMD
L6
FLASHING/COURTESY LIGHT
L7
PREFLASH/PAUSE FLASHING
LEV
MENU LEVEL
1. SOFT STOP:
The control unit is factory set with the Soft Stop function disabled. If you
wish to enable this function, proceed as follows: ensure you have enabled
Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV) and then use the
SEL key to select blinking LED L1 and press the SET key; at the same time
LED L1 becomes steady on and programming will be completed. With the
Soft Stop function enabled, at the end of the movement the control unit will
reduce operator force to zero gradually in a 2 second interval. Repeat the
procedure if you wish to restore the previous configuration.
2. SOFT START:
The control unit is factory set with the Soft Start function disabled. If you
wish to enable this function, proceed as follows: ensure you have enabled
Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV) and then use the
SEL key to select blinking LED L2 and press the SET key; LED L2 becomes
steady on and programming will be completed. With the Soft Start function
enabled, at the start of each movement the control unit will control start-
up of the operator, gradually increasing the force from the minimum to the
value set by the "FORCE" trimmer during the first 2 seconds of operation.
Repeat the procedure if you wish to restore the previous configuration.
Note: when the Soft Start function is enabled, the control unit automatically
disables the Starting Torque function, while if Soft Start is disabled then
Starting Torque is automatically enabled.
3. RELEASE STROKE:
The control unit is factory set with the release stroke function disabled.
This function comprises sending a closing command for 2 seconds at
the start of an opening cycle: this facilitates release of the lock to allow
correct execution of the opening cycle. If you wish to enable the Release
Stroke function at the maximum power, proceed as follows: ensure you
have enabled Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV) and
then use the SEL key to select blinking LED L3 and press the SET key; LED
L3 becomes steady on and programming will be completed. If you wish
to enable the Release Stroke function at the power set via the "FORCE"
Trimmer, repeat the operation described by pressing the SELECT key twice
(LED L3 will blink rapidly) rather than once. Repeat the procedure if you wish
to restore the initial configuration.
4. SLAM LOCK:
The control unit is factory set with the Slam Lock function disabled. This
function consists in adding, in the case of a deceleration stage during
closing, 1 extra second at the maximum power or at the power selected
with trimmer VR1, in such a way as to ensure positive engagement of the
gate lock, if installed. If you wish to enable the Slam Lock function at the
maximum power, proceed as follows: ensure you have enabled Extended
Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV) and then use the SEL key to
select blinking LED L4 and press the SET key; LED L4 becomes steady on
and programming will be completed. If you wish to enable the Slam Lock
function at the power set via the "FORCE" Trimmer, repeat the operation
described above, pressing the SEL key twice (LED L4 will blink rapidly)
rather than once. Repeat the procedure if you wish to restore the initial
configuration.
5. PED CMD ELECTRIC LOCK ACTIVATION. (ELS/CMD PED):
The control unit is factory set with the function for electric lock activation via
the Pedestrian command disabled. The function for electric lock activation
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
3 FLASHIES
with the Pedestrian command is used when, for example, the application
consists of a sliding gate with a pedestrian gate alongside. With this function
enabled the sliding gate can be opened both using commands from the
P/P Pushbutton and the remotes, and via the PED commands from the
pedestrian gate by activating the electric lock. To enable this function
proceed as follows: ensure you have enabled Extended Menu 3 (blinking 1
1 1 0 1 1 1 0 of LED LEV) and then use the SEL key to select blinking LED
L5 then press the SET key; LED L5 becomes steady on and programming
will be completed. Repeat the procedure if you wish to restore the previous
configuration.
6. FLASHING LIGHT OPERATION/COURTESY LIGHT:
The control unit is factory set with Flashing Light during Pause Time
disabled. If you wish to enable this function proceed as follows: ensure you
have enabled Extended Menu 3 (blinking 1 1 1 0 1 1 1 0 of LED LEV) and
then use the SEL key to select blinking LED L6 and press the SET key; LED
L6 becomes steady on and programming will be completed. Repeat the
procedure if you wish to restore the previous configuration.
Courtesy Light Operation: The 24 Vac 4W max. Courtesy Light output
will switch on for 3 minutes whenever an opening command is transmitted
7. PREFLASHING/PAUSE FLASHING:
The control unit is factory set with the Preflashing and Pause Flashing
functions disabled. If you wish to enable the Preflashing function, proceed
as follows: ensure you have enabled Extended Menu 3 (blinking 1 1 1 0
1 1 1 0 of LED LEV) and then use the SEL key to select blinking LED L7
and press the SET key LED L7 becomes steady on and programming will
be completed. If you wish to enable the Pause Flashing function repeat the
operation described above, pressing the SEL key twice (LED L7 will blink
rapidly) rather than once. Repeat the procedure if you wish to restore the
initial configuration.
Preflashing Operation: The 230 Vac and 24V flashing light output will
always switch on 3 seconds before the gate starts the closing operation..
Pause Flashing Operation: The 230 Vac and 24V Flashing Light output
will switch on if previously programmed The Pause Time.
RESET
If it becomes necessary to reset the control unit to restore the factory
settings, press the SEL and SET keys together; this will cause all the RED
indicator LEDs to light simultaneously followed immediately by the control
unit switching off.
DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating cycle
a functional test of the connected photocell is performed. In the case of an
open circuit and/or malfunctioning of the photocell, the control unit does not
enable movement of the gate and visually signals the test failed condition by
causing all the indicator LEDs to blink simultaneously. As soon as correct
operation of the photocell is restored the control unit is ready for normal
use. This operating mode guarantees failure monitoring in compliance with
EN 954-1 Category 2.
Commands input test:
In correspondence with each low voltage command input the control unit
is equipped with a signalling LED so that the status of the input can be
checked at a glance.
Operating logic: LED on input closed, LED off input open.
COMUNELLO ®Copyright 2014 - All right reserved
27