Fig. 8 / Afb. 8
Type
A
Type
Type
Modelo
mm
ETC 85 S
676
ETC 170 S
676
ETC 250 S
676
ETC 340 S
676
Tab. 2 / Tableau 2 /
Tabela 2 / Tabla 2
Fig. 9 / Afb. 9
1 2
B
C
D
mm
mm
mm
58
110
-
58
150
147
58
225
225
58
300
303
and also possibly contamination.
The local building and garage regulations
are to be considered. The appliance is not
designed for an excessive additional
vertical load.
Flooring
Care should be taken that
- the floor at the place of installation of
- the temperatures at the bottom of the
- the surface is level so that the heat
2.2.2 Connecting leads
The cross section of the connecting lead
is dependent upon
- the connected load of the heat storage
- the power supply company regulations,
E
F
The local regulations apply.
Connection
The lead feed-through aperture is on the
bottom right at the rear of the appliance.
mm
mm
The connection plate with the tension
∅ 6
390
relief and the connecting terminal block is
∅ 6
390
on the bottom right at the front. The
∅ 6
390
connection plate is removed from the
∅ 6
390
appliance for installation purposes by
undoing the two lateral screws and is
afterwards firmly replaced.
2.2.3 Fastening
Remove the wall mounting secured on
the rear of the appliance by undoing the
screws and fit at the desired place as
shown in figure 8. Next, vertically align the
heat storage unit in front of the wall
mounting and connect it to the bracket
with the screws. Firmly tighten the
fastening screws only after the storage
core has been inserted.
2.2.4 Inserting the storage core and the
- Remove the screws on the bottom left
- Pull the front panel/cover assembly
- Remove the internal partition after
- Remove the heating element with
English
the heat storage unit has a sufficient
load- carrying capacity. In cases of
doubt, a building expert should be
consulted.
appliance are permitted for the floor.
storage unit can be closed after
inserting the bricks and causes no noise.
unit
if any.
heating elements
and right of the front panel of the
appliance and pull off the two control
knobs (on the left and right of the
appliance).
from the bottom approx. 20 mm from
the appliance and then remove it from
the appliance in an upward direction.
removing the tapping screws
arranged at the top.
transport securing device from the