ENGLISH
INSTALLATION
1. TURNING OFF THE ELECTRICITY
Verify the wall switch is in the OFF position.
•
Turn off power at the circuit breaker that supplies power to the outlet box you are working on.
•
For screw-in type fuses unscrew the fuse that supplies power to the outlet box you are working on.
•
2. REMOVING THE COVER
Loosen the Light fixture cover screws (C) using a Phillips screwdriver and remove the cover (A).
•
(Fig. 2).
NOTE: The Light fixture cover screws (C) come pre-assembled on the light fixture.
3. KNOCKING OUT HOLES ON THE MOUNTING BASE PLATE
Attach the EVA foam (DD) to the back side of the mounting base with aligh holes.
•
Measure the distance of the mounting threaded holes on the junction box and find
•
the corresponding knock-out holes in the fixture's mounting base plate (D).
Use a hammer and a flat head screwdriver (or power drill with drill bit) to knock out two
•
(or four) holes in the mounting base plate (D) in the desired location to align properly
with the junction box
3
D
4. MAKING THE ELECTRICAL CONNECTIONS
Junction Box
Follow the wiring instructions given below to make the electrical connections. (Fig. 4A).
•
Surface Conduit Mount
Remove the conduit plug (B) from the bottom of the fixture using a drill and thread the wires from
•
the conduit inside the fixture through the hole.
Make wiring connections inside the fixture as per the instructions given below. (Fig. 4B)
•
ON/OFF Wiring (Non Dimming) Method
If necessary, strip 3/8 in. of insulation from the junction box or fixture (A) wires (Fig. 4C).
•
Connect the fixture black wire to the supply black wire ((+) line), and fixture white wire to the supply
•
white wire ((-) common) by twisting the exposed wires together and using the wire nuts (BB).
Ensure there are no loose wires.
Connect the supply ground wire to the green fixture ground wire by twisting the exposed wires
•
together and using the wire nuts (BB)
0-10V Dimmable Wiring Method
Connect the fixture black wire to the supply black wire ((+) line), and fixture white wire to the supply
•
white wire ((-) common) by twisting the exposed wires together and using the wire nuts (BB).
Ensure there are no loose wires.
Connect the supply ground wire to the green fixture ground wire by twisting the exposed wires
•
together and using the wire nuts (BB).
Connect the purple wire to the (V+) DIM wire and the pink wire with (V-) DIM wire by twisting the
•
exposed wire together.
NOTE: Hold stripped ends near each other and align any frayed strands (do not twist wires). Push the wires into
wire nut (BB) and use your fingers to twist the wire nut clockwise until tight. Check for tightness by pulling wires.
Mini Wallpack Instructions
www.cooperlighting.com
WARNING: Risk of electric shock. Disconnect power
at fuse or circuit breaker before installing or servicing.
DD
2
4A
Junction Box
4C
4D
IL51886022
1
A
4B
Surface Mount
B
Non-Dimming Wiring Diagram
(+) Line
Black
(-) Common
White
Lighting
Fixture
Ground
Green
0−10V Dimming Wiring Diagram
Black
(+) Line
(-) Common
White
Purple
(+) DIM V+
Lighting
Pink
(-) DIM V-
Fixture
Ground
Green
C
3/8 in.
3