Customer
Responsibilities
Before Daily or
after
Every
Every
_ach
each
40
100
Yearly
L_se
use
hours
_ours
Check Safety Valve
Drain Tank
Air Filter
•1
9
Air compressor pump intake
and exhaust valves
1- more frequent in dusty or humid conditions
Risk of Unsafe
Operation. Unit
cycles automatically
when power is
on. When servicing, you may be
exposed to voltage sources,
compressed
air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to the
air compressor, bleed tank of
pressure, and allow the air
compressor to cool.
To ensure efficient operation and
longer life of the air compressor
outfit, a routine maintenance
schedule should be prepared and
followed. The above routine
maintenance schedule is geared to
an outfit in a normal working
environment operating on a daily
basis. If necessary, the schedule
should be modified to suit the
conditions
under which your
compressor
is used. The
modifications
will depend upon the
hours of operation and the working
environment.
Compressor
outfits in
an extremely dirty and/or hostile
environment will require a greater
frequency of all maintenance checks.
NOTE: See "Operation"
section for
the location of controls.
To Check
Safety
Valve
Risk of Bursting. If
the safety valve
does not work properly, over-
pressurization
may occur, causing
air tank rupture or an explosion.
1.
Before starting compressor,
pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve is
stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
To Drain Tank
1.
Set the On/Auto/Off
lever to
"OFF" and unplug unit.
2.
Pull the regulator knob out and
turn counter-clockwise
to set the
outlet pressure to zero.
3.
Remove the air tool or
accessory.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5.
Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of tank.