Idiomas disponibles

_Risk
of Unsafe Operation,
Unit cycles automatically
when
power ison, When servicing,
you may be exposed
to
voffage sources,
compressed
air, or moving parts, Before servMng
unit
unp{ug or disconnect
emectdcamsupply to the air compressor,
Meed tank
of pressure,
and allow the air compressor
to cool
PROBLEM
Excessive
tank
pressure
- safety
valve
pops off.
Air Ieaks at
fittings.
Air leaks at or
inside check
valve.
CAUSE
Pressure switch does not
shut off motor when
compressor
reaches
"cut-out"
pressure.
Air leaks in air
tank or at air
tank welds.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Check valve seat damaged.
CORRECTION
Move On/Auto/Off
lever to
the "Off" position,
if the
outfit does not shut off
contact a Trained Service
Technician.
Air Ieaks at
Defective pressure switch
pressure switch
release valve.
release valve.
Defective air tank.
Air tank must be replaced.
Do not repair the leak.
Leaking sea!.
Air leaks
between head
and valve plate.
Contact a Trained Service
Technician.
Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution. Do Not
Overtighten,
A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor
is shut off. Reptace check
valve. Refer to the "To
RepIace or Clean Check
VaNe" in the "Service and
Adjustment"
section.
Contact a Trained Service
Technician.
Do not drill into, weBd or
otherwise
modify air tank
or it will weaken,
The tank
can rupture
or explode,
Contact a Trained Service
Technician.