Descargar Imprimir esta página

YZAKI 2/10 Manual De Uso página 26

Publicidad

Idiomas disponibles

Idiomas disponibles

t
abLeaux des taux recommandés
Check your values and correct them at least once a week.
Parameter
Target values
Salinity
pH level
Free chlorine
From 0.5 to 3.0
concentration
! important!
Stabilizer rate
From 20 to 50
(Cyanuric
acid)
Additional tests
Total alkalinity
From 80 to 150
(TA)
Water
From 150 to 300
hardness
WARNING - the presence of iron in your water (ferruginous water) may lead to rust
deposits in your pool and require the use of a metal sequestrant - please consult a
professional.
g
eneraL characteristics
The salt water chlorinator uses the latest electronic control technology, combining performance and ease
of use. You can easily adjust the production of disinfectant ta suit your needs, maximizing efficiency while
remaining environmenlally friendly. ln addition ta these easy-to-use setlings, il also has a selfcleaning
funclion for the cell and a self-test mode in the event of a warning or error code.
For example, the chlorinator displays a warning when its detects low salinity levels, improper temperatures
or a lack of water flow (see section "Error codes and solutions", page 39).
In its compact format, the chlorinator and its control box are integrated for easier installation and greater
space savings. The water inlet and outlet are on the same axis, reducing the need ta rearrange piping.
|
26
EN
Once the salt is dissolved in the water(+/- 24 to 48h), salt concentration
3 to 4 g/l
will only vary slightly over the course of the season.
Please note, a pH above 7.8 suppresses the disinfectant properties of
7.2 to 7.4
hypochlorite.
Measurements must be taken from around the return jets when the
chlorinator is switched on, preferably in the morning and out of direct
ppm
sunlight.
Conversely, with tao high a level of stabilizer, the hypochlorite will be
blocked. If the stabiliser level is too low, the hypochlorite will turn back
into salt too quickly, without having had time to disinfect sufficiently.
Conversely, if the stabiliser level is too high, the hypochlorite will be
ppm
blocked.
If the stabiliser level is too high, the pool will have to be partially drained
and water without stabiliser added.
This level measures the concentration of minerai salts (carbonates,
bicarbonates, hydroxides) in the water. Il stabilizes / buffers the water
ppm
balance. High TAC levels interfere wilh the effects of pH regulation and
scale deposits may begin ta appear.
Water hardness represents the amount of calcium carbonate present in
ppm
your water.
DESCRIPTION
Comments

Publicidad

loading

Productos relacionados para YZAKI 2/10

Este manual también es adecuado para:

4/206/30