Configuration
Condensed programming menu
This allows for the most-used parameters to be quickly configured. Press the SET key for 3 seconds to access it.
Condensed programming menu
OUT OF
PROGRAMMING
Temperature
indication
Parameters
Temperature setting (Set Point)
SP
SELFDRIVE Mode 0=Deactivated 1= Activated
CE
Probe 1 differential (Hysteresis)
C1
Defrost frequency (Time between 2 starts)
d0
Maximum defrost duration (0=defrost deactivated)
d1
Final defrost temperature (by probe) (If P4 ¹ 1)
d4
Status of the fans during the defrost 0=Shut down; 1=Running
F3
Alarm for maximum in probe 1 (It should be higher than the SP)
A1
Alarm for minimum in probe 1 (It should be lower than the SP)
A2
Defrost strategy in SELFDRIVE mode
d30
* According to wizard.
20 sec.
Parameters
3 sec.
Change
parameter
OK
Description
28
IN PROGRAMMING
Values
Change
value
OK
20 sec.
1652H4A11 Ed. 10
Value Min. Def. Max.
ºC/ºF
-50 0.0 99
0
1
1
ºC/ºF
0.1 2.0 20.0
0
6
96
0
*
255
ºC/ºF
-50 8.0 50
0
0
1
ºC/ºF
A2
99
99
ºC/ºF
-50 -50 A1
0
5
10