HMI (Keypad) and Basic Programming
4 HMI (KEYPAD) AND BASIC PROGRAMMING
4.1 USE OF THE HMI TO OPERATE THE INVERTER
Through the HMI, it is possible to command the inverter, visualize and adjust all of
its parameters. The HMI presents two operating modes: monitoring and setting. The
functions of the keys and the fields of the display active on the HMI vary according to
the operating mode. The setting mode is composed of three levels.
- When in the setting mode, level
1: press this key to return to the
monitoring mode.
- When in the setting mode, level 2:
press this key to return to level 1 of
the setting mode.
- When in the setting mode, level
3: press this key to cancel the new
value (new value is not saved) and
return to level 2 of the setting mode.
- When in the monitoring mode: press
this key to increase the speed.
- When in the setting mode, level 1:
press this key to go to the previous
group.
- When in the setting mode, level
2: press this key to go to the next
parameter.
- When in the setting mode, level
3: press this key to increase the
content of the parameter.
Press this key to define the motor
rotation direction.
Active when:
P0223 = 2 or 3 in LOC and/or
P0226 = 2 or 3 in REM
Press this key to commute between
LOCAL and REMOTE mode.
Active when:
P0220 = 2 or 3
Press this key to accelerate the motor up to the speed set in P0122 within the time determined
by the acceleration ramp. The motor speed is kept while the key is pressed. When the key is
released, the motor decelerates within the time determined by the deceleration ramp, until it
stops.
This function is active when all the conditions below are met:
1. Turn/Stop = Stop;
2. Enable general = Active.;
3. P0225 = 1 in LOC and/or P0228 = 1 in REM.
20 | CFW500
- When in the monitoring mode: press this key
- When in the setting mode, level 1: press this
- When in the setting mode, level 2: press this
- When in the setting mode, level 3: press this
- When in the monitoring mode: press this key
- When in the setting mode, level 1: press this
- When in the setting mode, level 2: press this
- When in the setting mode, level 3: press this
Figure 4.1: HMI Keys
- English -
to enter the setting mode.
key to select the desired parameter group – it
shows the parameter group selected.
key to show the parameter – it shows the
content of the parameter in order to change
the content.
key to save the new content of the parameter
– it returns to level 2 of the setting mode.
to decrease the speed.
key to go to the next group.
key to go to the previous parameter.
key to decrease the content of the parameter.
Press this key to accelerate the motor within
the time determined by the acceleration ramp.
Active when: P0224 = 0 in LOC or
P0227 = 0 in REM
Press this key to decelerate the motor within
the time determined by the deceleration ramp.
Active when:
P0224 = 0 in LOC or
P0227 = 0 in REM