Minimum clearance from sides and back of unit to
combustible construction, 91.44 cm (36") from
sides and 91.44 cm (36") from back
All internal packaging removed.
Knobs turn freely.
Burners are tight and sitting properly on orifices.
Pressure regulator connected and set. Gas
connections to grill using hose & regulator
assembly provided (pre-set for 11 in wc).
Unit tested and free of leaks.
User informed of gas supply shut off valve location
LP GAS TANK REQUIREMENT
A dented or rusty LPG tank may be hazardous and should be
checked by your LPG supplier. Never use a cylinder with a
damaged valve.
LP GAS HOOK-UP
Ensure that the black plastic grommets on the LPG cylinder
valve are in place and that the hose does not come into
contact with the grease tray or the grill head.
CONNECTION
Your grill is equipped with gas supply orifices for use only
with liquid propane gas. It is also equipped with a high
capacity hose/regulator assembly for connection to a suitable
gas cylinder. Please refer to "LP-gas supply system" for more
details. Below are the steps for cylinder connection:
1.
Make sure tank valve is in its full off position (turn
clockwise to stop).
2.
Make sure all burner valves are in their off position.
3.
Inspect valve connections, port, and regulator assembly.
Look for any damage or debris. Remove any debris.
Inspect hose for damage. Never attempt to use
damaged or obstructed equipment. See your local LPG
gas dealer for repair.
Installer Final Check List
USER, PLEASE RETAIN THIS MANUAL FOR FUTURE
REFERENCE.
PROPANE CYLINDER CAUTIONS
a)
Do Not store a spare LPG-gas cylinder under or
near this appliance.
b)
NEVER fill the cylinder beyond 80 percent full.
c)
If the information in "a" and "b" is not followed
exactly, a fire or explosion causing death or serious
injury may occur.
4.
When connecting regulator assembly to the valve, hand
tighten the quick coupling nut clockwise to a complete
stop. Do not use a wrench to tighten. Use of a wrench
may damage the quick coupling nut and result in a
hazardous condition.
5.
Open the tank valve fully. Apply the soap solution with
a clean brush to all gas connections. See below. If
growing bubbles appear in the solution the connections
are not properly sealed. Check each fitting and tighten
or repair as necessary.
6.
If you have a gas connection leak you cannot repair,
turn gas OFF at supply tank, disconnect fuel line from
your grill and contact our customer service at
ServiceDK@nexgrill.com or your gas supplier for repair
assistance.
7.
Also apply soapy solution to the tank seams. See below.
If growing bubbles appear, shut tank OFF and do not
use or move it! Contact an LPG gas supplier or your fire
department for assistance.
To disconnect LPG gas cylinder:
1.
Turn the burner valves off.
2.
Turn the tank valve off fully.
3.
Detach the regulator assembly from the tank valve by
turning the quick coupling nut counterclockwise.
7