EN
Controller
The whole controller is a button operated panel. If the display is not
operated for 30 seconds, the display goes to sleep and is locked and
the M1/ M2/M3/M4 cannot be used. You can continue to use the
display when it lights up by pressing the "" or "" button.
Up/Down
Drive the desk to the desired height when pressing and holding ""
or "" button.
Memory Button
When the desk reaches the height that you want to memorize,
press and hold any of the M1/M2/M3/M4 button for 5 seconds. When
you hear the sound "beep", this height is memorized in the
corresponding memory button. Recall the stored height by pressing
the corresponding button.
Setting Button (M4)
When you need to set the relevant parameters, please press and
hold the "M4" button for 10 seconds.
Display Screen
Displays the height value of the desk.
Initialization Settings
Initialization: When the system is abnormal and the display shows
"RST", please press the " " button until the product is lowered to the
lowest height and the product bounces back after hearing a "beep"
sound, then the initialization is completed. (Tip: In the process of
operation, do not release the button, otherwise the initialization will
fail) .
Forced initialization: Please press the " " button until the product
drops to the lowest height, then release the button and press the " "
button again for about 5 seconds until you hear a "beep" sound and
the product bounces back, then the initialization is completed.
System Reset: When the product is replaced with a new controller
or the parameters need to be restored to the factory settings, press
the " " and " " button at the same time, the first "beep" sound will be
heard after about 5 seconds, and the second "beep" sound will be
heard after 10 seconds. After the display shows "RST", please press
the " " button until the product drops to the lowest height, and the
product bounces back after hearing a "beep" sound, then the reset
is completed.
Safety Function
The table top will automatically spring back when it encounters
reverse resistance during ascent or descent.
Error No. & Solution
Error No.
Description
E01, E06, E07
Power Error
E04
Controller
connection error
E05
Reverse run
prompt when
blocked
E08
Desktop tilting
while running
E11, E21, E40,
Connection cable
E41
failure
E12, E22, E42,
Controller failure
E43
E14~E17,
Motor failure
E24~E27
E18, E28
Weight overload
HOT
Running timeout
Advanced Function Setting
To set a height limit:
Press and hold " " and " " at the same time for 5 seconds at the
desired height, then you will hear a buzzer sound, indicating that
the minimum/maximum limit is set successfully.
(The set value is ≤ 96, the default setting is the lower limit, the set
value is ≥ 97, the default setting is the upper limit)
To cancel this function, first run to the limit height, press and hold " "
and " " again for 5 seconds, when hearing the buzzer sound, the
limit is canceled.
Screen lock setting:
Press and hold " " and "M4" at the same time for 5 seconds, when
the display shows "LOC", it means the system is locked.
Press and hold " " and "M4" at the same time for 5 seconds, when
the display shows normal number, it means the system has been
unlocked.
Rebound sensitivity setting:
Based on safety design, the product will bounce back when it
meets resistance during operation. Its trigger rebound based on
current detection to improve product safety performance, but the
sensitivity is set too high, may cause unnecessary triggering. If the
frequent occurrence of false triggering, the rebound sensitivity can
be appropriately reduced, the factory default sensitivity setting value
is 4.
22
Solution
Replace power supply
Re-plug the controller
cable
Bounce alert, normal
Check the desktop
(perform initialization 1)
Check the cable (perform
initialization 1)
Replace the controller
Replace the motor
Remove the items on the
desktop (perform
initialization 1)
Stop using and resume
automatically after 20
minutes