Especificações Técnicas
8.2.1 Normas Consideradas
Normas de
UL 508C - power conversion equipment
Segurança
UL 61800-5-1 - adjustable speed electrical power drive systems - part 5-1: EMC safety requirements - electrical,
thermal and energy
UL 840 - insulation coordination including clearances and creepage distances for electrical equipment
EN61800-5-1 - safety requirements electrical, thermal and energy
EN 50178 - electronic equipment for use in power installations
EN 60204-1 - safety of machinery. Electrical equipment of machines. Part 1: general requirements
Nota: Para ter uma máquina em conformidade com essa norma, o fabricante da máquina é responsável pela
instalação de um dispositivo de parada de emergência e um equipamento para seccionamento da rede
EN 60146 (IEC 146) - semiconductor converters
EN 61800-2 - adjustable speed electrical power drive systems - part 2: general requirements - rating specifications
for low voltage adjustable frequency AC power drive systems
Normas de
EN 61800-3 - adjustable speed electrical power drive systems - part 3: EMC product standard including specific
Compatibilidade
test methods
Eletromagnética
CISPR 11 - industrial, scientific and medical (ISM) radio-frequency equipment - electromagnetic disturbance
(*)
characteristics - limits and methods of measurement
EN 61000-4-2 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques - section
2: electrostatic discharge immunity test
EN 61000-4-3 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques - section
3: radiated, radio-frequency, electromagnetic field immunity test.
EN 61000-4-4 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques - section
4: electrical fast transient/burst immunity test
EN 61000-4-5 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques - section
5: surge immunity test
EN 61000-4-6 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques - section
6: immunity to conducted disturbances, induced by radio-frequency fields
Normas de
EN 60529 - degrees of protection provided by enclosures (IP code)
Construção
UL 50 - enclosures for electrical equipment
Mecânica
IEC 60721-3-3 - classification of environmental conditions - part 3: classification of groups of environmental
parameters and their severities - section 3: stationary use at weather protected locations level
(*) Normas atendidas com instalação de filtro RFI externo. Ver