5. Operation
5.1
DT-Mobil Easy
5.1.1
Storage
During transport and storage, do not expose the
DT-Mobil Easy to direct sunlight for an extended
period of time. Excessive heating can lead to a
reduction in the quality of the fuel.
If overpressure occurs in the closed container as a
result of heating, it is released via vent valve C.
i
Important!
Do not stack filled tanks on top of each
other!
Suitable storage conditions:
Ambient temperatures from -10 °C to +40 °C.
Level surface.
Hood for outdoor storage.
Stackability: max. two empty tanks
5.1.2
Loading the filling station
Risk of injury!
The cover must be closed and complete-
ly sealed with closure G.
5.1.2.1 Loading by hand
An empty DT-Mobil Easy can be loaded by hand
using the recessed grip on the side of the tank.
Note the weight of the empty system:
39 kg
5.1.2.2 Loading with forklift
i
Important!
For safe lifting
with a forklift,
use the moul-
ded recesses
on the under-
side.
20
Recessed grip
Loading with forklift
5.1.3
Transporting
During transport, observe the pertinent regulations
for transport and securing loads, in particular:
Road traffic (licensing) regulations of the coun-
try concerned
CEN 12195 Parts 1 to 4 for calculation and
lashing
Use the belt recesses for fastening by means of
suitable tension belts on the transport vehicle.
i
Important!
Form before force!
First, try to load the filling station using
a positive connection (e.g. by slinging to
the sides).
Excessive lashing forces may deform the
tank and thus damage it.
Recommendation:
Use a non-slip mat.