3
5
Fig. 5. Contents of the battery module packaging.
Item
Description
1
Battery module
2
Warranty leaflet
3
Rack brackets and fixing screws
2 plastic parts to extend the base of the UPS and to
4
enable the battery module to be mounted on it, when
mounted as a tower.
Cable for interconnection of the battery module with
5
the UPS or with another module.
Kit of extendable rails for rack mounting and screws for
6
fastening
Tab. 3. List of battery module contents.
Once the reception is completed, it is advisable to re-pack
•
the UPS until it is put into service in order to protect it against
mechanical shock, dust, dirt, etc.
The packaging of the device consists of a cardboard or wooden
•
box, depending on the item, expanded polystyrene corners,
polyethylene cover and strapping, all of which are recyclable
materials. When the packaging requires disposal, it must be
carried out in accordance with current laws.
We recommend keeping it for at least 1 year.
5.1.2. Storage.
The device should be stored in a dry, ventilated room and
•
protected from rain, dust, and water or chemical splashes. It
is advisable to keep each device and battery unit in its original
packaging, as it has been specifically designed to ensure
maximum protection during transportation and storage.
For devices that contain Pb-Ca batteries, the charging
•
times indicated in Tab. 2 of document EK266*08,
determined by the temperature to which they are exposed,
must be respected, otherwise the warranty may be invalidated.
After this period, connect the device to the mains together
•
with the battery unit if applicable according to the instructions
described in this manual and charge for 12 hours.
Then disconnect and store the UPS and batteries in their
•
original packaging, noting the new date for recharging the
USER MANUAL
4
6
Quantity
1
1
2
1
1
1
batteries on a document as a record or even on the packaging
itself.
Do not store the devices where the ambient temperature
•
exceeds 50ºC or drops below -20ºC, as this may cause
degradation of the electrical characteristics of the batteries.
5.1.3. Unpacking.
The packaging of the device consists of a cardboard box,
•
expanded polystyrene (EPS) or polyethylene foam (EPE)
corners, polyethylene cover and strapping, all of which are
recyclable materials; consequently, if it requires disposal,
it must be carried out in accordance with current laws. We
recommend keeping the packaging in case it needs to be used
in the future.
Proceed as follows:
•
Cut the straps around the cardboard box.
Remove the accessories (cables, brackets, etc.)
Remove the device or battery module from the box with
the help, if necessary, of a second person depending on
the weight of the model or using appropriate mechanical
means.
Remove the protective corners from the device and the
plastic bag.
Do not leave the plastic bag within the reach of
children to avoid danger of suffocation.
Inspect the device before proceeding and, in the event of
finding damage, contact the supplier / distributor or, failing
that, our firm.
5.1.4. Transport to the site.
It is advisable to move the UPS using the most suitable means
•
for this. If the distance is considerable, it is recommended to
transport the device in its packaging to the installation site and
then unpack it.
5.1.5. Siting, immobilising and considerations.
All
SPS.ADVANCE RT2
devices are designed for rack mounting
•
(horizontal installation in 19" cabinets) or tower mounting
(vertical installation) as with their optional battery modules.
Follow the instructions indicated in relation to either of the two
possibilities, according to the particular configuration of your
device.
.. show, by way of example, illustrations of a device with or
•
without battery module. These illustrations provide help and
guidance on the steps to follow, but the instructions are not
intended to refer to a single model, although, in practice, the
actions to be carried out are always the same for all of them.
For all instructions regarding connections, refer to section .
•
5.1.5.1. Rack-type mounting in a 19" cabinet.
Proceed as follows (see Fig. 4):
•
Using the supplied screws, fix the two adapter angles for
SPS.ADVANCE RT2 UNINTERRUPTIBLE POWER SUPPLY (UPS)
47