TIGHTEN THE CONNECTION BETWEEN THE CONTROL VALVE
AND VESSEL
This is the threaded joint (C) in picture above where the control
valve joins onto the brine tank. Hold the vessel steady inside the
tank and twist the control valve tight.
CLEAN THE INJECTORS
Unplug the control valve.
Turn the bypass valves fully anticlockwise into bypass position
(perpendicular).
Using a screwdriver, remove injector screen and injector cap (A)
Use a screwdriver to unscrew the outer injector (B).
Insert the screwdriver and unscrew the inner injector (C).
Tilt the unit to remove the inner injector. Caution the unit may be
heavy, seek assistance.
Remove the screen gauze.
Clean screen gauze using a fine brush.
Flush the gauze with water until clean.
Flush water into the injector recess of the valve to flush out debris.
Clean the injector with a pin or paperclip.
Lubricate the O­rings on the injector. Lubricate the injector cap and
lubricate the injector screen with silicone lubricant.
Reinstall the injector, injector cap and injector screen. Do not over­
tighten the plastic cap. Seat the cap lightly into position. Over
tightening may cause breakage of the plastic cap that may not be