Help in the event of faults

9.1
LED displays String
Meaning for the corresponding strings
status (1)
Constant
|
green light.
|
|
Flashing
If DC disconnect is switched on (On):
green light.
|
SmartConnect
Operating manual

Can be detected on SmartConnect

+
+
-
-
OK
OK
N
L
120VAC
230 V
Line
230VAC
(1)
(2)
(1) LED display CAN distributor
(2) LED display, power supply
(3) LED displays, string status
(4) DC disconnect
LED displays, string status
Voltage of the relevant strings
300 V < U
< 1000 V.
DC
Current of the relevant strings I < 20 A.
Auxiliary voltage supply (230 V
present.
Switch-on delay for the relevant strings,
e.g. to protect the relay contacts.
9 Help in the event of faults
(3)
Action
No measures necessary.
|
) is
AC
No measures necessary.
|
(4)