The purpose of the regulator filter unit plus lubricator (FRL) is to filter the air, adjust the
pressure and lubricate it.
The "FRL" unit supports a maximum input pressure of 18 bar and has an adjustment range
of 0.5 to 10 bar. The setting may be modified by pulling the handle out and then turn-
ing. After adjusting, return the handle to the locked position by pushing down (fig.46a).
The lubricant flow-rate is adjusted by turning the screw on part "L", (fig.46b); normally
this unit is precalibrated to a pressure of 10Bar, with SAE20 viscosity lubricant in order
to make a drop of lubricant come out, which can be seen from the specific cover, every
4 times the bead breaker is operated.
Periodically check the lubricant level through the specific windows and top up as shown
in fig.46c. Top up only with non-detergent SAE20 oil equal to 50cc.
The filter regulator "FR" has an automatic condensation drain system, therefore in condi-
tions of normal use special maintenance is not required. The condensate may however
be drained manually at any time (fig.46d).
a
b
c
d
e
46
Normally the cups do not need to be removed, but check if this is necessary for mainte-
nance operations after a long period of use. If a manual operation is not sufficient, use
the specific key provided (fig.46e).
Clean with a dry cloth. Avoid contact with solvents.
FITLINE 32 - 32 2V - 32 GP - 32 GP 2V
126
User Manual