CAPSPRAY X 80
SETTING THE ASCENDING FEED PIPE
Spraying object lying on floor (fig. 12)
Turn rotating lever clockwise as far as it will go.
Spraying object over head (fig. 13)
Turn rotating lever counter-clockwise as far as it will go.
SETTING THE SPRAY GUN / STARTING OPERATION
5
STARTING OPERATION
Before connecting to the electrical outlet make
i
sure that the outlet voltage corresponds to the
operating voltage on the rating plate. The unit
must be connected with a properly grounded
shockproof socket.
Keep the turbine at the maximum possible distance
from the spray area to safeguard against explosion
or fire that may be caused by sparking electrical
parts.
1.
Plug the turbine power cord into a grounded, 3-slot receptacle.
2.
Attach the air hose to the air outlet on the turbine.
3.
Attach the air hose to the air inlet on your spray gun.
4.
Open closing lever on the paint container, remove paint
container.
5.
Fill paint container with coating material.
Do not overfill the container.
i
6.
Fit the appropriate filter to the feed tube depending on the
coating material used (Fig 1, item 24/25)
Low-viscosity coating materials
Viscous coating materials
7.
Check that the paint container seal is clean and is seated correctly.
8.
Clip the container onto the spray gun and secure with the closing
lever.
9.
Plug in the power cord.
10.
Turn on the turbine and begin spraying.
Fine filter (red)
Coarse filter (white)
7