Descargar Imprimir esta página

Zenit Grey Serie Manual De Instalacion Y Uso página 32

Electrobombas sumergibles
Ocultar thumbs Ver también para Grey Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Safety, Installation and Operations Manual - Original instructions
3.4 Permitted installation types
Make sure that the atmosphere in the working area is not potentially explosive.
3.4.1 Installation with DAC coupling device
With this type of installation (Fig. 13), the pump can be removed from and replaced in the tank quickly without any work on the system.
EN
Installation procedure (See APPENDIX 1 page 130)
1. Check that the pump is disconnected from the power supply panel and the impeller turns in the correct direction using the procedure described
in the manual.
2. Fix the flange to the pump's outlet with the screws provided.For models with hooks, fix the hook to the pump body using the screws provided.
3. Place the coupling device on the bottom of the tank and mark the position of the holes required to fix it.
4. Make holes of suitable diameter for the coupling device fixing slots and secure it firmly to the bottom of the tank using chemical or expansion
plugs. Use stainless steel metal fasteners or protect the screws and nuts with a suitable product to prevent corrosion.
5. Connect the outlet pipeline to the coupling device. A shut-off valve and a ball type check valve with full free passage should be installed using
a connection pipe with length equal to at least 5 times the diameter of the outlet.
6. Fit the pipe guides, cut to the correct length, to the coupling device. Galvanised steel pipes, or preferably stainless steel pipes, of suitable dia-
meter can be used (see technical information).
7. Connect the spacer bracket to the top end of the pipe guide and mark the positions of the holes required to fix it to one of the sides of the tank;
make sure that the pipe guides are perfectly vertical with the aid of a plumb-line or a spirit-level.
CAUTION
Before connecting the bracket spacer check, by lifting the pump up, if it is possible to extract the coupling flange from
the pipe guides (Fig. 14).
8. Make holes of suitable diameter for the spacer bracket fixing slots and secure it firmly using chemical or expansion plugs. Protect the screws
and nuts with a suitable product to prevent corrosion.
9. Clean the tank to remove any remaining debris and waste.
10. Secure a chain or sling of suitable size to the handle and lower the pump into the tank, sliding the flange along the pipe guides until it reaches
the coupling device.
11. Secure the electric cables so that they cannot be twisted or torn or drawn in by the pump.
12. Bring the cables out of the tank through a clean, smooth duct. Do not lay cables with tight bends or in positions with risk of crushing or damage.
13. Connect the electric cables to the control panel.