5.6 Motor outlet direction change
Careful! Careful! All operations must be performed with the cooker hood disconnected
from electricity and only by a professional and authorized technician.
Note: To exhaust the air through the upper part of the cooker hood or through its back (see
the images
6b
6a
according to the instructions below.
1.
Remove the grease filter. See the image
2. Use the screwdriver to remove the screws of the PCB box cover and take the PCB box
cover out of the cooker hood. See the image
3. Remove the screws securing the motor assembly housing from the top of the cooker
hood. See the image
4. Remove the motor assembly housing mounting screws from the back of the cooker
hood. See the image
5. Remove the entire motor assembly with the housing from inside the cooker hood. See
the image
6g
6. Rotate the motor assembly housing to change the direction of the air discharge. See the
image
6h
7. Reposition and fix the PCB box cover again, with the screws. See the image
8. Fasten the fixing screws again of the motor assembly housing in the upper part of the
cooker hood. See the image
9. Fasten the fixing screws again of the motor assembly housing from the back part of the
cooker hood. See the image
10. Install the cooker hood's grease filter. See the image
5.7 Carbon filter kit (code: TCF1) for operation in air recirculation mode
In the air recirculation mode, carbon filters capture substances with unpleasant odors. By
regularly replacing the carbon filters, a high degree of elimination of unpleasant odors is
ensured. Carbon odor filters cannot be cleaned or regenerated.
5.8 Fitting the carbon filter kit TCF1 - optional
1.
Turn off the unit.
2.
Remove the grease filter.
3.
Position the TCF1 carbon filters in the unit to the left and right of the engine.
See the image
7a
4. Correctly align the filter with the engine mount and attach it.
See the image
7b
5. Turn clockwise for a firm fit, each filter separately. See the image
6. After mounting both TCF1 filters, mount the grease filter.
5.9 Removing the carbon filter kit TCF1
1.
Turn off the unit.
2.
Remove the grease filter.
3.
Turn counterclockwise each individual TCF1 filter and pull to the side of the engine. See
the image
7d
4. Turn counterclockwise each individual TCF1 filter and pull to the side of the engine. See
the image
7e
5. Remove the TCF1 carbon filters from the unit. See the image
), it is necessary to change the direction of the motor from the inside