SPLIT 1X1
AROMA 2E
WIRING
SAFETY PRECAUTIONS
ATTENTION
• Be sure to disconnect the power source before working on the unit.
• All electrical wiring must be done in accordance with local and national regulations.
• A qualified technician must perform electrical wiring. An incorrect connection may cause a electrical
malfunctions, injuries and fires.
• A separate circuit and a single outlet must be used for this unit. DO NOT connect another product or
charger in the same outlet. If the capacity of the electrical circuit is not sufficient or there is. A defect
in the electrical work may result in electric shock, fire, or property damage.
• Connect the power cable to the terminals and secure it with a clamp. An unstable connection can
cause a fire.
• Make sure that all wiring has been done correctly and that the motherboard cover is control is correctly
installed. Otherwise, overheating may occur in the connection points, fires and electric shocks.
• Make sure that the main source connection is made through a switch that disconnects connects all
poles, with a contact gap of at least 3 mm (0.118").
• DO NOT modify the length of the power cord or use any extension cord.
CAREFUL
• Connect the cables of the outdoor unit before connecting the cables of the indoor unit.
• Be sure to ground the unit. The ground wire should be away from pipes gas pipes, water pipes, lightning
rods, telephones, or other ground wires. A bad connection grounding may cause electric shock.
• DO NOT connect the unit to the electrical supply until the wiring and plumbing are completely you get high
• Be sure not to cross electrical wiring with signal wiring, as this may cause distortion. sions and interfe-
rences. Follow these instructions to avoid distortion when the compressor starts:
• The unit must be connected to the power outlet. Normally, the power supply It should have a low output
impedance of 32 ohms.
• No other equipment must be connected to the same power circuit.
• Unit power information can be found on the specifications label of the product.
TAKE NOTE OF THE FUSE SPECIFICATIONS
The circuit board (PCB) of the air conditioner is designed with a fuse to provide overcurrent protection.
Fuse specifications are indicated on the circuit board:
OUTDOOR UNIT: T20A/250VAC (for units <24000 Btu/h), T30A/250VAC (for units >24000 Btu/h).
NOTE: THE FUSE IS MADE OF CERAMIC.
INSTALLATION MANUAL
7. WIRING
55