ELECTRICAL SPECIFICATION
The Reversible Vane pump should be wired to an overcurrent pro-
tected distribution panel fitted with a 15 amp breaker or fuse that
is specific to the Reversible Vane Pump circuit. Connect the orange
motor lead to positive and the black motor lead to negative.
Model
Voltage DC
18680-1000
12
MINIMUM WIRE SIZES
Wire Length Between Battery and Motor
1-10 ft (3m)
11-20 ft (6m)
21-30 ft (9m)
NOTE: To prevent motor damage, use only multi-strand copper
wire in size recommended.
WIRING DIAGRAM
Overload
Protected
Distribution
Panel
Battery
OPERATION
THE REVERSIBLE VANE PUMP IS DESIGNED FOR INTERMITTENT
DUTY. DO NOT OPERATE PUMP FOR MORE THAN 30 MINUTES
CONTINUOUSLY.
Rotary Vane pumps must NOT be run dry, as the pumped liquid is
the lubricant for the rotor and vanes. Observe the outlet and shut
off pump as soon as liquid stops flowing. The pump cannot run
against a closed outlet.
Pressure for normal operation should not exceed 20 feet of head
(8.7 psi).
Excessive pressures will cause fuse to blow. Temperature of
pumped liquid may be in the range of 45°-165°F (10°-78°C).
EXPLODED VIEW
Vue éclatée / Explosionszeichnung / Vista esplosa
Explosietekening / Sprängvy / Vista explotada
AMP Draw
Fuse Size
8
15 Amp
12V
#16 (1.5mm²)
#14 (2mm²)
#12 (3mm²)
Orange
Black
Discharge
Discharge
counter
clockwise
clockwise
rotation
rotation
MAINTENANCE
Check wires and connections to be sure corrosion is not adding
additional resistance to the motor circuit and causing a low
voltage condition at the motor. Low voltage can inhibit motor from
starting and cause fuse to blow.
Full voltage should be available to prevent motor damage. If
pump is to be used for water in freezing temperatures, drain by
loosening end cover screws.
DISASSEMBLY
1. Remove end cover screws, end cover and O-ring.
2. Withdraw rotor and vanes.
3. Loosen and remove the two slotted hex screws, which attach
body to motor.
4. Tap body lightly between ports and remove body from motor.
5. With a 1⁄ 2 " (12.7mm) diameter dowel, push against the shaft
seal from back (motor) side of the body to dislodge seal from
the seal bore.
NOTE: Do not tamper with or disassemble motor.
6. Remove slinger.
ASSEMBLY
Reference image on page 5
7. Replace slinger.
8. Lubricate seal with oil and position it in seal bore with lip, or
hollowed out side of seal, pointing towards the rotor/vane
bore.
With a 1⁄ 2 " (12.7mm) diameter dowel, push against the shaft
seal into its bore until it contacts the bottom.
9. Lubricate motor shaft and install body on motor.
10. Aligning flat in rotor with flat on motor shaft, install rotor.
Install vanes in vane slots of rotor.
11. Install O-ring and end cover. Tighten end cover screws.
EXPLOSION HAZARD: If pump is operated
in an area containing flammable vapors, wire leads
must be joined by insulated mechanical locking
connectors. Loose or inadequate wire connections
can spark resulting in an explosion. Property
damage, injury or death can occur.
PARTS LIST
Key
Description
1
End Cover Screw Kit (3/Kit)*
2
End Cover
3
O-ring*
4
Vanes (set of 5)*
5
Rotor*
6
Seal*
7
Slinger*
8
Grommet Kit (4/kit)
9
Motor Kit
Service Kit
* Parts Contained in Service Kit.
3
Reference image on page 4
Part Number
91004-0090
18647-0000
Use 90200-0001
Use 90200-0001
Use 90200-0001
Use 90200-0001
Use 90200-0001
92900-0120#
18753-0067
90200-0001
Qty.
1
1
1
1
1
1
1
1
1