7.6.9. Calibration of the pH measurement
Menu
7.6.10. Adjustment of the reversal frequency of the current supplying the cell
I .
Reversing the flow aims to prevent limescale deposits on the cell. The frequency at which flow is reversed
must be correctly set following the table below in order to ensure that the cell continues to operate correctly over
the long term.
Water hardness (°f)
Reversal frequency (hours)
Menu
7.6.11. Selecting the operating mode of the electrolyser
Possible settings
Menu
(depending on the
7.6.12. Setting the production setpoint
Electrolyser
operating mode
%
Default display
Important note: It is not possible to measure the level of free chlorine in your pool.
You will have to proceed empirically to adjust the setpoint.
Do not take into account the chlorine values given in the maintenance manual.
7.6.13. Setting the pH setpoint
Menu
Possible settings
From 6.5 to 7.5, in increments of 0.1.
0 to 5
16
Possible settings
From 2 to 24 h, in increments of 1.
model)
Continual
%
production setpoint.
OFF
Deactivation of the electrolyser.
Menu
Specific instructions
Directly select a value
using the
confirmation required).
Possible settings
From 6.8 to 7.6, in increments of 0.1.
5 to 12
12 to 20
10
8
Meaning
production,
buttons (no
Default setting
Measurement displayed
20 to 40
40 to 60
6
Default setting
Default setting
at
the
For DUO models: %.
Possible settings
From
1
to
100%,
increments of 1.
0% or OFF (depending on
the operating mode of the
electrolyser).
Default setting
7.2
> 60
4
2
6 h
Default setting
in
100%
13