VBM DOMOBAR Manual De Instrucciones página 54

Ocultar thumbs Ver también para DOMOBAR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4
2
20
5
3
7.6,
STEAM DISPENSING.
6
· Lift the switch lever (1) to "ON", the lamp (2) lights.
· Automatically is inserted resistance to heat water in the
boiler indicated by lighting the lamp (3).
· Wait until the set temperature is reached indicated by the
turning off of the lamp (3).
· Place the switch lever (1) to "OFF", the lamp (2) goes out.
1
· Turn the steam lance (4) to the bowl and then make a
short supply dispense of steam by slowly turning the
knob (5) counterclockwise to remove any residual water
present in the circuit.
ATTENTION: Do not leave for a long time the
switch (1) on, the water pump continues to
operate by pumping water in the boiler. Leave
inserted the switch (1) the time required for
the hot water supply.
ATTENTION: immediately after reaching the
set temperature of the steam given off by the
lamp (3) you must set the switch (1) to "OFF"
to prevent the burning of resistance.