- Up to three waste electrical devices per type of
device, with an edge length of no more than 25
centimetres, can be returned free of charge to
the manufacturer without prior purchase of a new
device from the manufacturer or taken to another
authorised collection point in your vicinity.
- Further supplementary take-back conditions of
the manufacturers and distributors can be ob-
tained from the respective customer service.
• If the manufacturer delivers a new electrical appli-
ance to a private household, the manufacturer can
arrange for the free collection of the old electrical
appliance upon request from the end user. Please
contact the manufacturer's customer service for
this.
17. Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Engine does not start
Pump does not suck
Inadequate pump delivery
Thermal sensor switches
off the pump
28 | GB
Possible cause
No mains voltage
Pump impeller jammed and thermal
sensor has switched off
Suction valve not in the water
No water in the pump housing
Air in the suction line
Suction valve leaking
Filter (suction valve) clogged
Max. suction height exceeded
Suction height too high
Filter dirty
Water level dropping rapidly
Pump performance reduces due to
hazardous substances
Motor overloaded, friction too high
due to foreign bodies
www.scheppach.com
• These statements only apply to devices installed
and sold in the countries of the European Union
and which are subject to the European Directive
2012/19/EU. In countries outside the European Un-
ion, different regulations may apply to the disposal
of waste electrical and electronic equipment.
Remedy
Check mains voltage
Disconnect the pump from the power
supply, dismantle and clean the water hoses
and connections
Put the suction valve in the water
Fill the pump housing with water
Check the suction line for leaks
Clean suction valve
Cleaning the filter
Check suction height
Check suction height
Cleaning the filter
Position suction valve lower
Clean pump and replace worn parts
Dismantle the pump and clean, avoid
sucking in foreign bodies

Publicidad