Descargar Imprimir esta página

turbionaire elva 60 Manual De Usuario E Instrucciones De Instalación página 22

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
5.5 Installation of the air adapter (reduction).
1.
Fix the reduction with the diameter of 150 mm on the connection of the hood.
See image
5
2. Fix the 120 mm diameter exhaust pipe on the reducer.
3. Seal the joints.
5.6 Fitting/ Unmount the grease filters
1. Unlock and pull down the perimeter suction panel first
2. Unlock the grease filter
3. Remove the grease filter
4. Install the filter, place the grease filter posts in the holes provided
5. Push the grease filter up and lock it in place
7c
5.7 Installation of the non-return valve
Position and secure on the hood connection. See image
Carbon filter kit (code: TCF1) for operation in air recirculation mode
In the air recirculation mode, carbon filters capture substances with unpleasant odors. By
regularly replacing the carbon filters, a high degree of elimination of unpleasant odors is
ensured. Carbon odor filters cannot be cleaned or regenerated.
5.8 Fitting the carbon filter kit TCF1 - optional
1.
Turn off the unit.
2.
Remove the grease filters
3.
Position the TCF1 carbon filters in the unit to the left and right of the motor.
Turn clockwise for a firm fit, each filter separately. See the image
4. After mounting both TCF1 filters, mount the grease filter.
5.9 Removing the carbon filter kit TCF1
1.
Turn off the unit.
2.Remove the grease filter.
3.Turn counterclockwise each individual TCF1 filter and pull to the side of the engine.
Remove the TCF1 carbon filters from the unit. See the image
5.10 Connection to the air recirculation system
Mount the carbon filters for odors (code: TCF1) - optional accessory. Attach the air exhaust
tube to the hood connection (optional accessory). Attach the TAD1ACC air deflector kit
(optional accessory). Make the connection to the hole in the built-in furniture (if it is
necessary). Fix the exhaust grille to the built-in furniture in such a way that its connection fits
into the exhaust pipe. Seal the joints.
5.11 Making the electrical connection
Insert the plug into the socket with protective contact.
5.12 Unit Disassembly
WARNING - Risk of injury!
Components inside the unit may have sharp edges.
Wear protective gloves.
1.
Disconnect the unit from the mains power supply.
2.
Undo the air exhaust tube.
3.
If necessary, open the filter cover (for models with this cover)
4.
Remove the grease filter. To prevent damage, do not bend the grease filter.
5.
Disconnect the control panel harness and the lighting system harness.
6.
Loosen the screws from the built-in furniture.
7.
Slowly lower the unit.
EN
6b
6c
22
6a
7b
8
9
10
7a
10
9

Publicidad

loading

Este manual también es adecuado para:

Elva 90