TROUBLE
SHOOTING
Grill will not light
• Is the 20 Ib LP gas fuel tank valve turned off?
Turn the 20 Ib LP gas fuel tank on.
• Is the grill properly
connected
to the gas supply?
Contact a trained repair specialist or see Installation Instructions.
• Is there gas in the 20 Ib LP gas fuel tank?
Check the gas level.
• Is the igniter working?
Check that the igniter battery is properly installed or check to see if
the battery needs to be replaced. See the "Replacing
the Igniter Battery" section.
Check to see if the grill will match-light.
See "Manually
Lighting the Main Grill" in the "Outdoor Grill Use" section.
Check for loose wire connections to the igniter or electrodes.
Check to see if debris is blocking the electrodes.
If a spark occurs anywhere but the igniter tip, replace the
igniter.
Burner flame will not stay lit
• Is the gas supply fully turned on?
Check that the 20 Ib LP gas fuel tank valve is fully open.
• Is the gas supply in the 20 Ib LP fuel gas tank low?
Check the gas level.
• Is the burner properly
installed
and in good condition?
Check that the burner is installed properly. Check for defects in
the burner.
Flame is noisy, low or erratic
• Is the gas supply fully turned on?
Check that the 20 Ib LP gas fuel tank valve is fully open.
• Is the gas supply in the 20 Ib LP fuel gas tank low?
Check the gas level.
• Does only one burner appear low?
Check and clean the burner ports if clogged or dirty. See
"General Cleaning" section.
• Is the gas supply hose bent or kinked?
Straighten the gas supply hose.
• Is the flame noisy or lifting away from the burner?
Burner may be getting too much air. Check the air shutter
adjustment,
see "Check and Adjust Burners" section.
• Is the burner flame mostly yellow or orange?
Grill may be in an area that is too windy, or not receiving enough
air. Check the burner air inlets for obstructions.
Excessive flare-ups
• Is there excessive
fat in the food being grilled?
Keep flame on low or turn one burner off.
Keep the hood up when grilling to avoid excessive flare-ups.
Move food to the warming rack until flames subside.
To avoid damage to the grill, do not spray water on gas flames.
Low heat
LP Gas:
For outdoor grills using a 201b LP gas fuel tank, slowly open the
tank valve.
NOTE: If flow limiting device activates, your grill may not light. If
your grill does light, the flames will be low and will not heat
properly.
1. Turn tank valve and all control knobs off and wait 30 seconds.
2. After shutting off the tank, very slowly open the tank valve and
wait 5 seconds before lighting.
3. Light the burners one at a time. See "Lighting the Main Grill"
section.
Natural Gas:
Gas pressure is affected by size and length of the gas line from the
house to the grill. Contact a qualified gas technician to provide the
Natural gas supply to the selected grill location in accordance
with
the National Fuel Gas Code ANSI Z223.1/
NFPA54 - latest edition and local codes.
ASSISTANCE
Before calling for assistance,
please check "Troubleshooting."
If you still need help, follow the instructions
below.
When
calling,
please
know
the
purchase
date
and
the
complete
model and serial number
of your appliance.
This
information will help us to better respond to your request.
If you need replacement
parts
If you have questions
or need to order replacement
parts,
contact Customer Service Center at 1-877-373-2301
Please direct all correspondence
to:
Nexgrill Industries, Inc.
5270 Edison Avenue, Chino, CA 91710
Please include a daytime phone number in your
correspondence.
Accessories
Natural Gas Conversion
Kit
Order Part Number 710-0003
Check the air shutter adjustment,
see "Check and Adjust Burners"
section.