8. Specifications
8. Specifications
Depending on the selected instrument version (e.g. seals) the specification may deviate from the specifications listed
here. The specifications in the order documentation are definitive.
For further specifications, see WIKA data sheet LM 40.05.
Specifications
Measuring range
Maximum working pressure
Overpressure limit per IEC 62828-1
Max. measured error per IEC 62828-1
Total probable error per IEC 62828-2
Output signal
Auxiliary power
Current supply
Pin assignment
Short-circuit resistance
Reverse polarity protection
Insulation voltage
Material (wetted)
Instrument
Cable
Protective cap
Material (in contact with the environment)
Measuring location marking
WIKA operating instructions submersible pressure sensor, model LS-1000
→ See product label
→ Corresponds to the upper measuring range value/measuring range full scale value
→ Any permanent operation above the maximum working pressure is not permissible.
1.5 times
→ The overpressure limit is based on the measuring range.
≤ ±0.5 % of span
■
≤ ±1.0 % of span
■
→ See table "Total probable error per IEC 62828-2" below
→ See product label
→ See product label
→ See product label
→ See product label
S+ vs. U-
U+ vs. U-
DC 750 V
Stainless steel 316L, epoxy resin
PVC
■
FEP
■
PVDF
PE (polyethylene)
EN
11