Operator Features; General Features - Erreka PUMA Manual Del Instalador

Accionador para puertas corredera
Ocultar thumbs Ver también para PUMA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DESCRIPTION OF THE PRODUCT
2

OPERATOR FEATURES

Model
Power supply (V/Hz)
Absorbed current (A)
Power consumed (W)
Capacitor (μF)
Protection class (IP)
Maximum torque (Nm)
Maximum speed (m/min)
Locking
Operating temperature (ºC)
Duty cycle S3 (%)
Weight (Kg)
Maximum weight of gate (kg)

General features

• Power supply (earthed):
PUS400EC: 230Vac/50Hz
PUS400ECM: 125Vac/60Hz
• Control of open/close by way of encoder
• Adjustable maximum thrust
• Adjustable standby time in automatic cycle
Notable features
Flashing light
The light remains on during the opening and closing
operations.
The light goes off when the operation finishes. The light
goes off whenever operation is interrupted at an
intermediate point.
Operation advance warning function
(DIP2=ON)
This function delays the start of operation by three
seconds, during which time the flashing light comes on
to warn us that operation is about to begin.
Traffic light
A plug-in receiver can be connected if the AEPS1-001
card is installed. Using colour lights, these will indicate
the suitability or otherwise of crossing the gate.
• Off: gate closed
• Green light: gate open, free passage
• Red light: gate in movement, passage forbidden
• Flashing green light: open gate about to close (in
automatic mode)
32
Installation Manual
PUS400EC
PUS400ECM
230/50
125/60
1,2
2,4
280
280
8
20
44
44
12
12
10
12
Yes
Yes
-20 / +55
-20 / +55
25
25
9
9
400
400
PUMA operators are constructed to form part of a
sliding gate automation system.
This operator, with built-in control panel, is equipped
with a slowdown system which reduces speed at the
end of the opening and closing operations, in order
to prevent impacts and bangs to the gate.
This operator allows us to fulfil the requirements of
standard EN 12453 without the use of peripheral
elements.
• Closing safety device cable connectors (photocells or
mechanical strips)
• Cable connector for emergency stop pushbutton
(STOP)
• Connector for plug-in receiver
• Connector for traffic light card
• 24Vac cable connector for peripheral connection
Slowdown function (DIP 8=ON)
Function which reduces the speed of the motor at the
end of the opening and closing operation.
STOP pushbutton (emergency stop)
This contro l pa nel allows an emergency stop
pushbutton to be installed (STOP). This pushbutton is of
NC type (normally closed). The opening of this contact
produces the immediate halting of the gate.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Puma pus400ecPuma pus400ecm

Tabla de contenido