Descargar Imprimir esta página

Sears Kenmore Quiet Comfort 758.144107 Manual Del Usuario página 13

Humidificador contemporaneo para toda la casa capacidad de 10 galones

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting
Trouble
Probable
Cause
Remedy
Power
light not illuminated
° No Power
° Check
120 volt power
source,
• Speed
control
in off posF
• Turn speed
control
clock-
tion (See page
7,)
wise.
Unit will not run and Fill
• Selected
humidity
level
• Raise
humidistat
setting
Light
is not on.
has been
established,
Note:
Red power
light
is on.
Unit will not cycle
on and
oft,
• Humidity
control
turned
al!
the way clockwise
to
"Constant
On" position,
• Desired
humidity
not
established,
• Humidifier
under
size for
requirements.
• Float
is not free,
• This is normal.
• Turn humidity
control
counter
clockwise
until the
fan turns
off.
• Allow up to 24 hours of run
time for unit to adjust.
• Designed to satisfy an
area up to 2100 sq. ft,
Unit will not shut off.
• Free float from obstruction.
Unit wil! not dry out
• A small
amount
of water
completely,
remains
in the base after
the Refill
Light comes
on,
Bottle
continues
to empty.
• Air is entering
the bottle,
Unit is not emptying
during
use,
• Dirty filter,
• Lower
spring
assembly
on
bottle
damaged
or missing
post in bottom
of base,
• Check
"E-Z-Fill
Side-Cap"
and lower spring
assembly
• Check
for leak in water
bottle.
• Ensure
gasket
for 'E-Z-Fill
Side-Cap"
is in place.
• Change
to a fresh new
filter,
• Check orientation
of bottle,
Reposition
so that lower
spring valve assembly
is
depressed
by post in
bottom
of base.
CAUTION:
Use only
42-14900
EPA Registered
Bacteriostat
available
from
Sears
Retail
store.
Use of other
water
treatment
products
may
damage
the fifter
component,
Under
no circumstances
should
you
use water
treatment
products
designed
for
Roto
belt
or Ultrasonic
humidifiers.
13

Publicidad

loading

Este manual también es adecuado para:

Kenmore quiet comfort 42-14410