6 - FURTHER DETAILS - ADVANCED MENU
The ADVANCED MENU allows the system to be further customised
by modifying parameters not accessible from the basic menu
To access the ADVANCED menu, press the MENU key and hold it
PARAMETERS
EL.F.
1
SP.h.
2
Ph.2.
3
tP.h.
4
Ed.m.
5
iE.D.
6
tE.D.
7
LP.o.
8
TP.C.
9
FP.r.
10
tP.r.
11
FC.Y.
12
tC.Y.
13
de.a.
14
se.r.
15
se.f.
16
de.f.
17
To set the default values: 1) access the advanced programming
function; 2) select the "dEf" parameter"; 3) activate the modification
mode ("0" on display"); 4) accept the modification (press "MENU"
24
DESCRIPTION
Electric brake
0 = off
1 = on
Use of PHOTO1 when starting from closed
0 = PHOTO1 is checked
1 = The gate starts even with PHOTO1 excited
Use of PHOTO2
0 = Enabled during both opening and closing AP/CH
1 =Only enabled during opening AP
Photo-device test
0 = off
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
Sensitive edge type
0 = contact (NC)
1 = resistive (8k2)
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
Edge test
0 = off
1 = on
Partial opening
Time for automatic closure from partial opening (0=off)
Flashing light output setup
0 = Steady
1 = Flashing
Pre-flashing time (0 = off)
Courtesy light setup
0 = On at end of operation for time TCY
1 = On if gate not closed + duration of TCY
2 = On if courtesy light timer (TCY) time not out
3 = Gate open light on/off
4 = Gate open light proportional flashing
Courtesy light on time
Hold-to-run
0 = off
1 = on
Service interval cycle threshold. Once the set
threshold is reached, the light flashes
at high speed in all subsequent cycles (only if FPR is
on).
(0 = off)
Enabling of continuous flashing indicating
service required (only active with gate closed).
0 = off
1 = on
Restoring the default values
down for 5 seconds
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU
DEFAULT
CONFIGURATION
0
1
0
0
1
0
0
30
20
1
0
0
0
0
0
0
and hold it down). A countdown should now appear: d80,d79...,d01
down to "
don
". Release the key when finished.
MIN
MAX
UNIT
x 0.01s
0
100
(step of 5)
0
1
0
1
0
3
0
1
0
1
0
1
0
100
% (step of 1)
0
900
s
0
1
0
10
s
0
4
s
0
900
(step of 10s)
0
1
x 1000
0
100
cycles
0
1