WEG WECM / Emerald eZA 14634998 Manual De Instalación, Operación Y Mantenimiento página 33

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE!
 The standard maximum speed value is preset at WEG to be the highest value of
the speed range but, can be changed by the user (see item 6.3).
 The product has speed memory when operating in local speed adjustment.
The last speed adjusted will be kept in memory when the input power supply is
removed. The motor will accelerate to the memorized speed when the input power
supply is reconnected.
 The local controls inside the opening on the back cover are totally insulated. There
is no risk of shock when touch any internal part of this opening, even when the
solution is running.
ATTENTION!
After remove and reinstall, make sure that the plastic lid from the back side of the drive
cover is securely closed to guarantee the protection degree.
 Remote speed adjust:
The speed can be adjusted by the input signals available in the control cable:
¶ DC voltage: 2 to 10V DC [tolerance: +10%];
¶ DC current: 4 to 20mA DC [tolerance: +10%];
¶ Frequency duty-cycle: 10 to 95%
»
Voltage: 10 to 24Vpk [tolerance: -5%/+10%];
Frequency: 80Hz [tolerance: -2,5%/+2,5%];
»
¶ The product will turn off if imposed signals lower than 2V DC, 4mA DC or 10%.
The speed can be adjusted using the external speed controller (see item 6.4).
Control input reference:
Signal
Condition
type
Lower than 2V DC
DC voltage
a
From 2 to 10V DC
Lower than 4mA DC
DC current
From 4 to 20mA DC
Lower than 10%
Frequency
From 10 to 95%
Notes:
a.
The DC voltage signal can be applied by an external power supply or using the built-in 10VDC
source and an additional potentiometer (5kΩ to 10kΩ);
b. Maximum speed adjusted (see item 6.3);
c.
Solution minimum speed (lowest value of the speed range);
d. Input signal (V DC, mA DC, %) supplied to the respective remote input.
Table 6 .1 - Control input reference
Resulting speed value
Zero (motor is off)
((Max
-Min
b
Zero (motor is off)
((Max
-Min
b
Zero (motor is off)
((Max
-Min
b
)/8)×(IS
-2)+Min
c
d
)/16)×(IS
-4)+Min
c
d
)/85)×(IS
-10)+Min
c
d
WECM / Emerald eZA Manual | 33
www.weg.net
Conductors
1
2
Blue
Red
Black
Brown

Publicidad

Tabla de contenido
loading

Tabla de contenido