Descargar Imprimir esta página

Mi-T-M Corporation AG2-PM14-08M1 Manual Del Usuario página 20

Publicidad

Idiomas disponibles

Idiomas disponibles

Operator's Manual
OPERATION
PRE-OPERATION:
Check the engine oil level before starting. (See engine manual.) Fill the fuel
tank according to the engine manual instruction.
Pump oil level should be checked before each use. Check the oil level indi-
cator on the pump crankcase. Make certain the oil is in the center of the oil
sight glass. If the level appears to be low, fill with SAE20 or 30 non-detergent
pump oil.
Remove any moisture in the unit's air tank.
WARNING: NEVER ATTEMPT TO OPEN THE AIR TANK DRAIN VALVE
WHEN MORE THAN 10 PSI OF AIR PRESSURE IS IN THE AIR
TANK!
Remove excessive pressure with an air tool, then open the Air Tank Drain
Valve in the bottom of the air tank. Close tightly when drained. Make sure the
Engine Switch is in the "OFF" position.
Make sure the Safety Relief Valve is working correctly.
Make sure all guards and covers are in place and securely mounted.
START-UP:
1. Read safety warnings before performing operation.
NOTE: Unplug all equipment from the power receptacles before starting
the unit.
2. Flip the toggle on top of the Pilot Valve to the upright position. This provides
a loadless start. The unit will unload and allow easier engine start-up.
3. Start the engine. (Refer to the Engine Manual accompanying this unit.)
4. When the engine has run for 1-2 minutes, flip toggle back to the original
position.
5. Set pressure by adjusting the Pressure Regulator counterclockwise for less
pressure and clockwise for more pressure. (Actual delivered pressure may
vary from pump maximum pressure rating).
6. Make sure the unit is grounded. See Grounding Instructions.
7. Loads can now be applied to the unit.
NOTE: This engine is equipped with a "Low Oil" shutdown system for
engine protection. The engine stops when the oil level gets too low.
The engine will not restart without adding oil.
If you notice any unusual noise or vibration, stop the unit and refer to "Trou-
bleshooting".
SHUTDOWN:
1. Remove all load by turning off electrical appliances and unplugging electric
cords.
2. Move the Engine Switch to the "Off" position. (Refer to the Engine Manual
accompanying this unit.)
3. Drain air from the air tanks by releasing air with an attached air tool or by
pulling on the Safety Relief Valve.
4. Once the Air Tank Pressure Gauge registers under 10 pounds, open the
drain valve under each air tank to drain any moisture.
5. Allow the unit to cool down.
6. Wipe the unit clean and store in a safe, non-freezing, dry area.
20

Publicidad