Descargar Imprimir esta página

Maytag Commercial MAT20MNTGW Manual De Instrucciones página 9

Ocultar thumbs Ver también para MAT20MNTGW:

Publicidad

Idiomas disponibles

Idiomas disponibles

LOCATION REQUIREMENTS
Selecting the proper location for your washer improves
performance and minimizes noise and possible washer "walk."
Your washer can be installed in a basement, laundry room,
or recessed area. See "Drain System."
Companion appliance location requirements should also be
considered.
IMPORTANT: Do not install or store the washer where it will
be exposed to the weather. Do not store or operate the washer
in temperatures at or below 0°C (32°F). Some water can remain
in the washer and can cause damage in low temperatures.
Proper installation is your responsibility.
You will need:
■ A water heater set to 49°C (120°F).
■ An earthed electrical outlet located within 1.2 m (4 ft) of
power cord on back of washer. See "Electrical Requirements."
■ Hot and cold water faucets located within 1.2 m (4 ft) of hot
and cold water fill valves on washer, and water pressure
of 138 kPa–690 kPa (20 psi–100 psi). A pressure reduction
valve should be used in the supply line where inlet pressure
entering the building exceeds 690 kPa (100 psi) to avoid
damage to the washer mixing valve.
■ Single washer installations require 300 mm (12") minimum
risers to provide an air cushion and avoid noise and damage
to valves.
■ A level floor with maximum slope of 25 mm (1") under entire
washer. Installing on carpet is not recommended.
■ Floor must support washer's total weight (with water and load)
of 143 kgs (315 lbs).
■ A floor drain under the bulkhead. Prefabricated bulkheads
with electrical outlets, water inlet lines, and drain facilities
should be used only where local codes permit.
Recessed Area or Closet Installation
This washer may be installed in a recessed area or closet.
The installation dimensions shown are the minimum spaces
allowable. Additional spacing should be considered for ease of
installation and servicing. Companion appliance spacing should
be considered.
Minimum installation spacing
356 mm
(14" maximum)
356 mm
(14" max.)
127 mm
(5")
127 mm
(5")
25 mm
(1")
76 mm
(3")
310 cm
(48 inch
406 mm
457 mm
(16")
(18")
25 mm
(1")
155 cm
(24 inch
76 mm
(3")
25 mm
(1")
2
)
2
2
)
2
9

Publicidad

loading

Este manual también es adecuado para:

Mat20cstgwMat20mntkwMat20mnagw