User manual
If the column does not stay in position, check the placement of the seal and the condition of the floor,
and repeat the previous operation.
Adjust the winch position to the desired working level. To do this:
- Raise the safety pin at the rear of the winch stand, and tilt the front of the mount upwards.
- Lower or raise the winch while keeping the safety pin raised and the bracket tilted to the desired working po-
sition. Please ensure that the notch is correctly located in the opening in the column.
Make sure that the column is correctly aligned with the panel being straightened.
- The pulling force produced by the winch is 350Kg and is delivered by a mechanical system with an auto-
matic load brake.
- To release the tension, simply turn the crank in the other direction. To make a downward pull, use the
pulley on the front of the Airfix and pass the cable underneath.
Always keep a minimum of 3 wraps around the winch spool.
MAINTENANCE
Dust removal can be done with a compressed air blow gun before cleaning. Clean the Airfix Draw Aligner with a
suitable cleaning product for painted steel surfaces. Follow the product's cleaning instructions. Wipe the Airfix Draw
Aligner with a cloth after cleaning. Never use a high-pressure washer, as this will damage the paint.
WARRANTY
The warranty covers any defects or manufacturing faults for two years, from the date of purchase (parts and labour).
The warranty excludes incidents due to misuse, dropping, dismantling, or any other damage due to transport. The
warranty does not cover normal wear and tear of parts if maintenance is not kept up to date. Only spare parts from the
manufacturer may be used for repairs.
TROUBLESHOOTING
When connected to the compressed air
network, no noise is
produced.
The Airfix Draw Aligner does not stick to the
floor.
Translation of the original
instructions
DEFECTS, CAUSES, SOLUTIONS
CAUSES
Fitting not properly connected.
No air in the network.
Poorly positioned seal.
Venturi not properly attached to the
plate.
Worn joint.
Floor condition.
Clogged muffler
AIRFIX DRAW ALIGNER
Solutions
Connect your compressed air fitting
firmly to the Airfix Draw Align
Check that your compressed air system
is working properly (valve closed)
Reposition the seal correctly in the
groove by placing it end to end (see
marking on the plate)
Tighten the two visible screws on the un-
derside of the plate with an H5 spanner.
Change the seal with a new one (contact
your distributor)
Position on a clean, non-porous floor
with no major imperfections.
Unscrew the silencer and blow it out. If
too dirty, change it. To access the silen-
cer, carry out step two in reverse order
15