Descargar Imprimir esta página

SPIDO SPIVARIO POOL 750 Manual De Instrucciones Original página 28

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
EN
3.0 - DESCRIPTION AND FUNCTIONS OF THE
BUTTONS
- "RUN/STOP" BUTTON:
Used to start or stop the pump.
• When the pump is switched off in manual mode, it
stops until it is switched on again.
• When switched off in automatic mode, the pump
will automatically turn on when the time reaches
the next programmed segment.
3.1 - "SET" BUTTON:
• In manual mode, it is used to switch between
different default speeds.
• In automatic mode, it is used to enter the
programming status or to enter the next item to be
programmed in each segment.
• In automatic mode, press and hold the button for 3
seconds to exit the segment.
3.2 - "UP" BUTTON:
• In manual mode, it can be used to increase the
speed of the pump.
• When used during the programming of the current
time, users can switch to the previous interface to
display the timing item page.
• When used in the programming of the automatic
mode "T" segments, it allows to increase the time
or speed in that segment.
• If you press and hold this key, the value change will
increase rapidly.
3.3 - DOWN BUTTON:
• In manual mode, it can be used to decrease the
speed of the pump.
• When used during the programming of the current
time, users can switch to the previous interface to
display the timing item page.
• When used in the programming of the automatic
mode "T" segments, it is used to decrease the
time or speed in that segment.
• If you press and hold this key, the value change will
decrease rapidly.
3.4 - FUNCTIONS OF THE «COMBINATION» KEY:
• Press the "UP" and "DOWN" buttons at the same
time to switch from "automatic mode" to "manual
mode".
• Press and hold the "RUN/STOP" button and the
"Set" button at the same time for 3 seconds to set
the current time. If you wish to cancel the setting,
press the "RUN/STOP" button again and the "Set"
button to exit.

Publicidad

loading