REMOTE PROGRAMMING BY TEXT MESSAGE

The dialler's features allow you to program one or more preset telephone numbers to which text messages
will be sent when specific events take place:
Any alarm signals on one or more of the 4 inputs.
Low Battery Test. 2 text messages can be programmed, one for malfunctions and one for resetting.
Periodic sending of a text message at programmed intervals.
Sending a text message to check the remaining credit.

Input Activation

The BTEL-GT can send a text message to the numbers in the phone book when an event activating the
inputs takes place. To do this, send a programming text message in the following format:
#Installer PIN#INA#Input#Receiving Numbers#Message Text#
where the following are enclosed by # signs:
Installer PIN; a numeric code of 5 digits (from 00000 to 99999).The factory default installer PIN is 11111.
INA; the command text that programs the activation of inputs.
Input; identifies the input (IN1, IN2, IN3, IN4 which correspond to inputs L1, L2, L3, and L4).
Recipient Number; position of the telephone number in the phone book (see "Paramaters Manage-
ment->Phone Book Management "). To send the text message to multiple numbers in the phone book,
separate the numbers with a comma (for example "2,3,5" sends the text message to the telephone
numbers stored under numbers 2, 3, and 5).
Message Text ; type the text message to send (maximum 100 characters).To disable sending of the
message not type the text.

Low Battery Power Message

When battery power is low, a text message can be sent to a preset telephone number. To do this, send a
programming text message in the following format:
#Installer PIN#BAT#Receiving Number#Low Battery Power Text#Battery Reset Text#Enable#
where the following are enclosed by # signs:
Installer PIN; a numeric code of 5 digits (from 00000 to 99999).The factory default installer PIN is 11111.
BAT; the program command to send a message informing that the battery power is low.
Recipient Number: type the phone number of the recipient (not its position in the phone book). The
telephone number may also be a number not found in the phone book.
Low Battery Power Text ; type the text message informing the recipient that the Battery Power is Low
(maximum 50 characters).
Reset Text ; type the text message to be sent to notify that the Battery Has Been Reset (maximum 50 characters).
Enable; type 1 to enable the sending of text messages or 0 to disable(in this case the fields Receiving
Number, Low Battery Power Text, and Reset Text will be disregarded).

Periodic Message

Send a programming text message by using the following formula:
#Installer PIN#PER#Receiving Number#Message Text#Interval#
where the following are enclosed by # signs:
Installer PIN; a numeric code of 5 digits (from 00000 to 99999). The factory default installer PIN is 11111.
PER; the program command to send periodic text messages.
Recipient Number: type the phone number of the recipient (not its position in the phone book). The
telephone number may also be a number not found in the phone book.
Message Text ; type the text message to send (maximum 100 characters).
Periodo; interval at which the message is sent, expressed in days, from 1 to 365 (type 0 to disable and
disregard the Message Text field).
The periodic message will be sent after the set number of days and always at the time of day
at which it was programmed.