Descargar Imprimir esta página

Pleasant Hearth ES-322-1 Manual Del Propietário página 11

Estufa eléctrica de 20 pulg. y 24 pulg.

Publicidad

Idiomas disponibles

Idiomas disponibles

BOTTOM PANEL
ELECTRIC WIRING DIAGRAM
Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in
accordance with national and local codes.
CIRCUIT DIAGRAM
S1
I/O
L
N
AC120V /
GND
60HZ
WARNING: DISCONNECT POWER
BEFORE SERVICING.
Disconnect power before servicing.
Any electrical re-wiring of this appliance must be done by a qualified electrician.
This wiring must be done in accordance with local codes and/or in Canada with
the current CSA C22.1 Canadian Electrical Code, and for US installations, the
National Electrical Code ANSI/NFPA No. 70.
If repairing or replacing any electrical component or wiring, the original
wire routing, color coding and securing locations must be followed.
THERMAL
BULB 1
40W
FLAME EFFECT
MOTOR < 4W
DANGER
THERMAL
CUTOFF
FUSE
BULB 2
S2
40W
750W
10
S3
HEATER
ELEMENT
FAN
MOTOR
20110715